Service Work PCB conveyor system 4.3.14 Replac ing the Proximity Switch for th e Adjustment Unit [03040795-xx] 108 Service Manual SIPLACE D1/D1i/D2/D2i The switching point is set at the actuator on the conveyor edge: ► P…

100%1 / 280
Service Work
4.3.14 Replacing the Proximity Switch for the Adjustment Unit [03040795-xx] (applicable to modular PCB conveyor only) PCB conveyor system
Service Manual SIPLACE D1/D1i/D2/D2i 107
4.3.14
4.3.14 Replacing the Proximity Switch for the Adjustment Unit [03040795-xx] (applicable to modular PCB conveyor only)
Replacing the Proximity Switch for the Adjustment Unit [03040795-xx] (applicable to
modular PCB conveyor only)
Overview
The proximity switch serves as a signal for controlling the pneumatic valve of the adjustment unit. Once
the switching point has been reached, the conveyor edge is connected via the short-stroke cylinder.
Removal/Installation
Parts
Proximity switch for adjustment unit 1 and 2
[03040795-xx]
Legend
1. Adjustment unit 1
2. Adjustment unit 2
3. Transport direction
Move the PCB conveyor to the position which gives
you best access to the adjustment system.
Move the Y gantries into the area outside the PCB
conveyor.
Switch off the machine and secure it to prevent unau-
thorized reactivation.
Switch off the compressed air supply.
Loosen the grub screw on the clamping device (1)
and unthread the connection cable as far as the con-
version board of the assembly tub.
Fit the new proximity switch and reconnect the sys-
tem to the electrical system.
Fix the proximity switch with the grub screw.
Tighten the grub screw to a torque of 20 Ncm
(+3 Ncm). The proximity switch must be level with the
adjustment unit housing (2).
Service Work
PCB conveyor system 4.3.14 Replacing the Proximity Switch for the Adjustment Unit [03040795-xx]
108 Service Manual SIPLACE D1/D1i/D2/D2i
The switching point is set at the actuator on the conveyor
edge:
Position the adjustment unit, with the help of the width
adjustment belt, so that the proximity switch can be
easily accessed.
Place a 4/10mm distance gauge on the adjustment
unit and press this distance gauge against the adjust-
ment unit.
Push the proximity switch upwards, as far as the stop
and tighten the fastening screw.
NOTICE!
Perform a width adjustment function test at all conveyor
sides.
Use the SITEST program to calibrate the conveyor
edges.
Service Work
4.3.15 Replacing the Light Barriers for Transmitter and Receiver Modules [03039283] PCB conveyor system
Service Manual SIPLACE D1/D1i/D2/D2i 109
4.3.15
4.3.15 Replacing the Light Barriers for Transmitter and Receiver Modules [03039283]
Replacing the Light Barriers for Transmitter and Receiver Modules [03039283]
4.3.15.1
4.3.15.1 Replacing the Transmitter
Replacing the Transmitter
Dismantle the holder and the transmitter.
Unscrew the transmitter from the holder.
Unthread the connection cable as far as the relevant plug in the conveyor edge.
Unplug the connector plug.
Rerun the connection cable accordingly and reconnect the plug on the conveyor edge to the electri-
cal system.
Fix the new light barrier in the original position.
Parts
Please note the different item numbers for the individual
light barriers - these are for the different lengths of the
connection cable.
Legend
1. Transmitter at input conveyor [03039283-xx]
2. Receiver at input conveyor [03039269-xx]
3. Transmitter at placement area [03039284-xx]
4. Receiver at placement area [03039270-xx]
5. Transmitter at output conveyor [03039285-xx]
6. Receiver at output conveyor [03039271-xx]
T = transport direction
NOTICE
Important instructions for replacing the light barrier
When looking in the direction of transport, the transmitter is always on the left.
Check whether it would be helpful to feed in the new cable with the aid of the old one, at
least in some areas.