Service Work C&P6/12 Head 4.4.5 Replacing the Turning Station (D Ser ies) [003 41780-xx] 120 Service Manual SIPLACE D1/D1i/D2/D2i See also   6.5.2 PCB B oards on t he 6/12 C&P Head [ ➙ 233] 4.4.5 4 . 4 . 5 R e …

100%1 / 280
Service Work
4.4.4 Replacing the Intermediate Distributor C&P6/12 Head
Service Manual SIPLACE D1/D1i/D2/D2i 119
4.4.4
4.4.4 Replacing the Intermediate Distributor
Replacing the Intermediate Distributor
Parts, equipment and tools
Intermediate distributor DLM2/DLM3 [00330648-xx] or
intermediate distributor DLM4 [03082809-xx]
Removal/installation
The following supply voltages and signals are routed by the intermediate distributor to the individual
placement head modules or to the head board:
Please observe the ESD regulations for the following
work and use an ESD ground strap.
Loosen the four fastening screws and remove the
cover (1), by pulling these off the 4 snap fasteners.
Undo the four spacer bolts (3) and tilt the intermedi-
ate distributor (2) a little.
Position of the sockets
1. Front of the intermediate distributor
2. Back of the intermediate distributor
U4 = pressure sensor
Carefully disconnect the hose from the pressure sen-
sor (U4).
Disconnect the connection plugs from their slots. Re-
fer to the circuit diagram folder for the relevant ma-
chine.
Remove the intermediate distributor.
Restore connections X1......X12.
Push the hose onto the pressure sensor tube (U4).
Fasten the intermediate distributor.
NOTICE
Settings, machine data
No settings are required.
The axis machine data can be saved in the memory of this board using the Head Exchange
option in the menu.
Service Work
C&P6/12 Head 4.4.5 Replacing the Turning Station (D Series) [00341780-xx]
120 Service Manual SIPLACE D1/D1i/D2/D2i
See also
6.5.2 PCB Boards on the 6/12 C&P Head [ ➙ 233]
4.4.5
4.4.5 Replacing the Turning Station (D Series) [00341780-xx]
Replacing the Turning Station (D Series) [00341780-xx]
Removal/Installation
Connectors Description
X1, 40-pole Connected to plug X14 on the head board
Voltage supply, tacho and track signals for the Z axis drive
Signal from light barrier "Z axis in top position"
Signal from light barrier "Z axis in bottom position" (sensor stop signal)
Control signal for the air blast valve
Supply voltage +5 VDC, ±15 VDC
Reference point signal for the DP axis
Track signals for the DP axis
X2, 40-pole Connected to plug X13 of the gantry head distributor
Voltage supply and track signals for the star axis drive
Reference point for the star axis
Analog air blast pressure value
Supply voltages +5 VDC, ±15 VDC, +24 VDC
X3, 10-pole Connection for the Z motor and Z tacho signal (Tacho signal is not use on the HF
machine)
X4, 10-pole Connection for the Z axis track signals
X5, 10-pole Connection for the star motor
X6, 6-pole Connection for the air blast valve
X7, 10-pole Connection for the DP axis track signals
X10, 10-pole Connection for the "Z axis up" signal (positioning unit)
X11, 8-pole Connection for the light barrier "Z axis down" signal (sensor stop signal)
X12, 10-pole Connection for the star axis track signals
X13, 10-pole Test connection for the Z axis track signals
X14, 10-pole not used
X15, 10-pole Test connection for the star axis track signals
X16, 10-pole Test connection for the DP axis track signals
Legend
1. Turning station
2. Fastening screw for turning station
NOTICE! The head does not need to be re-
moved when dismantling the turning station.
Switch off the machine and secure it to prevent unau-
thorized reactivation.
Open the strain relief at the gantry head distributor.
Disconnect the motor cable and flat ribbon cable from
the sockets on the gantry head distributor.
1
2
Service Work
4.4.6 Replacing the DP Rocker C&P6/12 Head
Service Manual SIPLACE D1/D1i/D2/D2i 121
4.4.6
4.4.6 Replacing the DP Rocker
Replacing the DP Rocker
The swivel-in rocker of the DP station has been fitted with 2 cones from version 7 onwards. The DP sta-
tion [00320041-05] can be upgraded to accommodate this improvement by simply replacing the old part.
Tools and Equipment
Standard tool
Retrofit assembly for rocker [03063649S01]
Belt tensioning device for DP station
Removal
Loosen the screw fastening the turning station (2).
Carefully lever the turning station (1) backwards, off
the locating pins and gently pull it (1) out.
Make sure that the contact surfaces on the turning
station and back part (3) are clean.
Insert the turning station holes (1) onto the parallel
pins.
Carefully push the turning station towards the front
part until it reaches the stop.
Move the C&P head to a suitable position. (Move the
X/Y gantry axes so that you can easily access the
turning station.)
Fasten the turning station with the screw provided (2).
Plug the cable into the slots on the gantry head dis-
tributor. Make sure the cables are run correctly.
Fasten the strain relief at the gantry head distributor.
Switch the machine on and start it up.
Use the SITEST program to run a function test.
3
1
2
Carefully disconnect the toothed belt from the motor
toothed wheel.
Loosen the two screwed fittings on the rocker arm.
NOTICE! The rocker arm is located under the
drive arm (3). The drive arm is fixed to the rocker arm with
the two screws (1).
Swing the rocker armon the motor to one side and re-
move the rocker arm with drive wheel (2) from the
swivel-in ball bearing.