00195376-05_SM_D1_D1i_D2_D2i_EN - 第171页

Service Work 4.5.5 Replacing the Main Head Board [00352833 -xx] Pick&Place Head Service Manual SIPLACE D1/D1i/D2/D2i 171 Removal/Installation 4.5.5 4 . 5 . 5 R e p la c in g t h e M a in H e a d B o a r d [ 0 0 3 5 2…

100%1 / 280
Service Work
Pick&Place Head 4.5.4 Z-axis Incremental Encoder (Read Head) on the P&P Head [03000102-xx]
170 Service Manual SIPLACE D1/D1i/D2/D2i
4.5.4
4.5.4 Z-axis Incremental Encoder (Read Head) on the P&P Head [03000102-xx]
Z-axis Incremental Encoder (Read Head) on the P&P Head [03000102-xx]
Overview
Turn the return unit (1) in the mount so that the cables
and plugs (2) do not touch the casing. This prevents
the cables being damaged during movement.
Fix the return unit (1) with the grub screw (3) to the
mount (4).
Legend
1. Z-axis incremental encoder (read head)
Service Work
4.5.5 Replacing the Main Head Board [00352833-xx] Pick&Place Head
Service Manual SIPLACE D1/D1i/D2/D2i 171
Removal/Installation
4.5.5
4.5.5 Replacing the Main Head Board [00352833-xx]
Replacing the Main Head Board [00352833-xx]
Removal
Remove the P&P head from the machine.
Loosen the two screws (4) fastening the mount at the
side.
Remove the cable ties and unplug the press-fit con-
nection (3).
Unthread the cable as far as the head board (5).
Loosen the screws (2) fastening the incremental en-
coder (1).
Unplug the press-fit connection (3) and extract the in-
cremental encoder (2).
CAUTION! Do not damage the incremental
scale!
The Z axis scale is situated under the incremental encod-
er.
Fit the new incremental encoder so that there is a gap
of 0.4 mm between it and the scale. Use the corre-
sponding thickness gauge (plastic).
Make sure that the mount and the incremental encod-
er are installed parallel to one another. Where neces-
sary, correct the play at the holes (within the
tolerance) and tighten the screws.
Check the track signals.
4
2
5
1
3
2
CAUTION
Digital pressure control valve
The digital pressure control valve needs to be fitted with version [00352833-09] of the head
main board.
NOTICE! Connectors
A number of connectors are unplugged during replace-
ment work. Always mark their original positions so that
these can be easily allocated again when service work is
finished.
Dismantle the relevant segment of the TwinHead.
Loosen the two screws (2) fastening the flat ribbon
cable clamp (1).
Service Work
Pick&Place Head 4.5.5 Replacing the Main Head Board [00352833-xx]
172 Service Manual SIPLACE D1/D1i/D2/D2i
Legend
1. Head main board (fitted on the top of the TWIN seg-
ment)
2. Fastening screws with spacer sleeves under the
board
3. Connectors (2 on gantry, 2 to segment)
Unplug all connectors (3) from the head main board
(1) (2 connectors from the TWIN segment, return cyl-
inder, Z axis incremental encoder).
Loosen the four fastening screws (2). Watch out for
the four spacer sleeves under the board. These can
be grasped and removed with a small Allen key.
Carefully pull the main head board (1) up and off. This
also disconnects the supply plug on the vacuum gen-
erator.
Completely open the connector fixtures on the foil flat
ribbon cableand remove the foil flat ribbon cable(1).