Service Work Pick&Place Head 4.5.6 Replacing the Control Cable for the DP Uni t - Force Sensor [03005289] 174 Service Manual SIPLACE D1/D1i/D2/D2i Removal/Installation NOTICE! Make s ure you note the correct con - ta…

Service Work
4.5.6 Replacing the Control Cable for the DP Unit - Force Sensor [03005289] Pick&Place Head
Service Manual SIPLACE D1/D1i/D2/D2i 173
Installation
4.5.6
4.5.6 Replacing the Control Cable for the DP Unit - Force Sensor [03005289]
Replacing the Control Cable for the DP Unit - Force Sensor [03005289]
Overview
► Connect the foil flat ribbon cable completely into the
connector (contacts must be fully covered) and fix the
connector strain relief.
► Carefully connect the new head main board (1). This
also reconnects the vacuum generator.
► Fit the fastening screws (2) with the spacer sleeves.
► Reestablish all connections to the electricity supply
(3).
► Fit the Twin segment again.
CAUTION
Transfer the machine data to the EPROM!
Transfer the machine data from the station to the intermediate distributor.
► Follow the instructions in "6.6.13 Transmitting the Head-Specific Data (from SW601)"
[ ➙ 260].
Legend
1. Control cable for DP unit/force sensor
2. Flat ribbon mount
3. Main head board
4. Force measuring board
► Remove the P&P head from the machine.
1
4
3
2

Service Work
Pick&Place Head 4.5.6 Replacing the Control Cable for the DP Unit - Force Sensor [03005289]
174 Service Manual SIPLACE D1/D1i/D2/D2i
Removal/Installation
NOTICE! Make sure you note the correct con-
tact position of the control cables during removal and in-
stallation. The installation position is marked in blue.
► Disconnect the control cable from the force measur-
ing board (1). To do this, pull the two locking handles
on the plug up and out.
► Loosen the two screws fastening the flat ribbon
mount (2).
⇨ To access the plug, the main head board (3) must
be removed.
► Remove the head main board (3). Take care not to
lose the four spacer sleeves.
► Disconnect the control cable (4) from the main head
board (3) and remove the control cable (4).
► Connect the new control cable to the main head
board (3) and fit the flat ribbon mount (2). Pull the
locking handle upwards.
► Insert the control cable (1) until the contacts (4) fully
engage.
NOTICE! Observe the original installation posi-
tion of the control cable.
► Push the two locking handles down. The control ca-
ble should now sit firmly on the plug (2) of the force
measurement board.
⇨ (3) To the main head board.
1
4
3
2
1
4
3
2

Service Work
4.5.7 Replacing the Stationary Digital Component/FC Camera [03020578-xx] Pick&Place Head
Service Manual SIPLACE D1/D1i/D2/D2i 175
4.5.7
4.5.7 Replacing the Stationary Digital Component/FC Camera [03020578-xx]
Replacing the Stationary Digital Component/FC Camera [03020578-xx]
Overview
Removal/Installation
Legend
1. Stationary component camera type 36 (type 33 can
also be fitted as an option)
2. FlipChip camera - stationary type 25 (FC camera)
Item numbers
▪ Stationary component camera P&P (type 36) 55x45
digital [03042491-xx]
▪ Stationary FC camera P&P (type 25) 16x16 digital
[03020578-xx]
► Move the component trolley out of the machine.
► Switch off the machine.
► Carefully lift the upper section (1) of the camera up
and out.
► If possible, avoid touching the camera lens system.
► Remove the camera cover (2).
► Unplug the electrical connections (CAN Bus cable,
Hotlink cable, voltage supply).
CAUTION! Component camera type 25
The four fastening screws holding the component cam-
era type 25 also hold the supporting plate of the camera
calibration point.
Make sure that the supporting plate does not drop down.
► First loosen the two upper fixture screws and replace
these two M6x35 screws with setting screws M6x50
[3005958-xx].
This fixes the "Caul for mark" in place.
► Now loosen the other two M6x50 fastening the base
plate of the stationary camera.