Service Work Pick&Place Head 4.5.6 Replacing the Control Cable for the DP Uni t - Force Sensor [03005289] 174 Service Manual SIPLACE D1/D1i/D2/D2i Removal/Installation NOTICE! Make s ure you note the correct con - ta…

100%1 / 280
Service Work
4.5.6 Replacing the Control Cable for the DP Unit - Force Sensor [03005289] Pick&Place Head
Service Manual SIPLACE D1/D1i/D2/D2i 173
Installation
4.5.6
4.5.6 Replacing the Control Cable for the DP Unit - Force Sensor [03005289]
Replacing the Control Cable for the DP Unit - Force Sensor [03005289]
Overview
Connect the foil flat ribbon cable completely into the
connector (contacts must be fully covered) and fix the
connector strain relief.
Carefully connect the new head main board (1). This
also reconnects the vacuum generator.
Fit the fastening screws (2) with the spacer sleeves.
Reestablish all connections to the electricity supply
(3).
Fit the Twin segment again.
CAUTION
Transfer the machine data to the EPROM!
Transfer the machine data from the station to the intermediate distributor.
Follow the instructions in "6.6.13 Transmitting the Head-Specific Data (from SW601)"
[ ➙ 260].
Legend
1. Control cable for DP unit/force sensor
2. Flat ribbon mount
3. Main head board
4. Force measuring board
Remove the P&P head from the machine.
1
4
3
2
Service Work
Pick&Place Head 4.5.6 Replacing the Control Cable for the DP Unit - Force Sensor [03005289]
174 Service Manual SIPLACE D1/D1i/D2/D2i
Removal/Installation
NOTICE! Make sure you note the correct con-
tact position of the control cables during removal and in-
stallation. The installation position is marked in blue.
Disconnect the control cable from the force measur-
ing board (1). To do this, pull the two locking handles
on the plug up and out.
Loosen the two screws fastening the flat ribbon
mount (2).
⇨ To access the plug, the main head board (3) must
be removed.
Remove the head main board (3). Take care not to
lose the four spacer sleeves.
Disconnect the control cable (4) from the main head
board (3) and remove the control cable (4).
Connect the new control cable to the main head
board (3) and fit the flat ribbon mount (2). Pull the
locking handle upwards.
Insert the control cable (1) until the contacts (4) fully
engage.
NOTICE! Observe the original installation posi-
tion of the control cable.
Push the two locking handles down. The control ca-
ble should now sit firmly on the plug (2) of the force
measurement board.
(3) To the main head board.
1
4
3
2
1
4
3
2
Service Work
4.5.7 Replacing the Stationary Digital Component/FC Camera [03020578-xx] Pick&Place Head
Service Manual SIPLACE D1/D1i/D2/D2i 175
4.5.7
4.5.7 Replacing the Stationary Digital Component/FC Camera [03020578-xx]
Replacing the Stationary Digital Component/FC Camera [03020578-xx]
Overview
Removal/Installation
Legend
1. Stationary component camera type 36 (type 33 can
also be fitted as an option)
2. FlipChip camera - stationary type 25 (FC camera)
Item numbers
Stationary component camera P&P (type 36) 55x45
digital [03042491-xx]
Stationary FC camera P&P (type 25) 16x16 digital
[03020578-xx]
Move the component trolley out of the machine.
Switch off the machine.
Carefully lift the upper section (1) of the camera up
and out.
If possible, avoid touching the camera lens system.
Remove the camera cover (2).
Unplug the electrical connections (CAN Bus cable,
Hotlink cable, voltage supply).
CAUTION! Component camera type 25
The four fastening screws holding the component cam-
era type 25 also hold the supporting plate of the camera
calibration point.
Make sure that the supporting plate does not drop down.
First loosen the two upper fixture screws and replace
these two M6x35 screws with setting screws M6x50
[3005958-xx].
This fixes the "Caul for mark" in place.
Now loosen the other two M6x50 fastening the base
plate of the stationary camera.