00195376-05_SM_D1_D1i_D2_D2i_EN - 第187页

Service Work 4.8.4 Replacing the Solenoid Valve s [03000630] Cutter Service Manual SIPLACE D1/D1i/D2/D2i 187 4.8.4 4 . 8 . 4 R e p la c in g t h e S o le n o id V a lv e s [ 0 3 0 0 0 6 3 0 ] Replacing the Sole noid Valv…

100%1 / 280
Service Work
Cutter 4.8.3 Replacing the Control Unit [03006411]
186 Service Manual SIPLACE D1/D1i/D2/D2i
Installation
4.8.3
4.8.3 Replacing the Control Unit [03006411]
Replacing the Control Unit [03006411]
Removal/Installation
Install the proximity switch (1) precisely in the position
you marked with the permanent marker.
Insert the prepared cylinder into the cutter, with the
correct rotary position of the articulated joint (2) i.e.
the joint axes must be vertical.
Fasten the cylinder in this position, with the 2 screws
provided (3).
Connect the compressed air hoses to the cylinder in
the correct allocation.
Check the gap between the leading edge of the tape
deflector and the "empty-tape baffle, inside".
Check the switching points of the proximity switches.
1
3
2
NOTICE
If the tapes are not cut correctly, even though the switching points have been set properly and
the short-stroke cylinder has been exchanged - complete with the one-way restrictor - the cause
of the problem may be:
Incorrect compressed air level
Leaking compressed air connection or Y-socket union
Legend
1. Control unit under the cover
Dismantle the waste slide.
Remove the cover (1) from the control unit.
1
Service Work
4.8.4 Replacing the Solenoid Valves [03000630] Cutter
Service Manual SIPLACE D1/D1i/D2/D2i 187
4.8.4
4.8.4 Replacing the Solenoid Valves [03000630]
Replacing the Solenoid Valves [03000630]
Overview
Mark the allocation of all press-fit connections and
disconnect all press-fit connections (2) from the con-
trol unit.
Remove the cable ties and the connection cable fix-
tures.
Carefully pull the control unit (3) off its mount (4).
Carefully insert the new control unit onto the mount,
in the correct rotary position and location, until it locks
into place.
Restore all plug-and socket connections in the cor-
rect allocation.
Run the connection cables and fasten with cable ties
(strain relief).
Check the jumper setting according to the label on
the control unit and adjust, if necessary.
Replace the control unit cover.
Fit the waste slide.
1
4
3
2
1. Position of the solenoid valves
1
Service Work
Cutter 4.8.5 Replacing the Proximity Switch [00332894]
188 Service Manual SIPLACE D1/D1i/D2/D2i
Removal/Installation
4.8.5
4.8.5 Replacing the Proximity Switch [00332894]
Replacing the Proximity Switch [00332894]
Overview
Removal/Installation
Legend
1. Solenoid valve assembly
Loosen the compressed air connections (3) on the
solenoid valve.
Unplug the press-fit connection (2) on the solenoid
valve connection cable.
Loosen the screws (4) holding the solenoid valve in
place and remove the solenoid valve.
Fit the new solenoid valve and establish the press-fit
connection to the valve.
Attach cable ties (strain relief) where necessary.
1
4
3
2
Legend
1. 2 proximity switches on each short-stroke cylinder
1
Use a permanent marker to mark the exact installa-
tion position (3) of the proximity switch (1) or (2) on
the short-stroke cylinder.
Loosen the screw fastening the proximity switch to
the short-stroke cylinder.
Unthread the connection cable to the control unit.
Install the proximity switch precisely in the position (3)
you marked with the permanent marker on the short-
stroke cylinder.
Secure the fastening screws with locking varnish.
Reconnect to the electricity supply.
Check the switching points of the proximity switches.
1
2
3
3