Settings Modular PCB Conveyor System 6.7. 12 Jumper Settings for Conveyor Control TSP 201 274 Service Manual SIPLACE D1/D1i/D2/D2i 6.7.12 6 . 7 . 1 2 J u m p e r S e t t in g s f o r C o n v e y o r C o n t r o l T S P 2…

Settings
6.7.11 Lifting Table Functions Modular PCB Conveyor System
Service Manual SIPLACE D1/D1i/D2/D2i 273
▪ Proximity switch on the lifting table cylinder
▪ Dynamic response of approx. 480 ms
6.7.11.1
6.7.11.1 Setting the Lifting Table Unit [00358684-xx]
Setting the Lifting Table Unit [00358684-xx]
6.7.11.2
6.7.11.2 Adjusting the Lifting Table Speed
Adjusting the Lifting Table Speed
Setting times for the lifting table
Setting the damping unit
The damping unit (1) allows the lifting table to move gen-
tly upwards. When the PCB is clamped, it also prevents
excessive bounce by the PCB.
► Check whether the damping unit is fixed with the lock-
nut (2) in the mounting block and that the plunger (3)
of the damping unit is just touching the actuator (4).
In this default setting, the lifting table should move up
gently.
► If this is not the case, loosen the locknut at the mount-
ing block and turn the damping unit approx. one rota-
tion into the mounting block..
► Start SITEST and move the lifting table up.
► The lifting table should move gently upwards.
The PCB clamping should not engage audibly and
there should be no PCB clamping error message.
► Check the speed of the lifting table and correct where
necessary.
Legend
1. Pneumatic valve
2. Lifting table cylinder with position query down
3. Piston rod
4. Adjustment valve – time characteristic for "lifting table
down"
5. Adjustment valve - time characteristic for "lifting table
up"
NOTICE! Rotating the adjustment valves in a
clockwise direction leads to slower movement.
Adjust the valves on the lifting table cylinder (4 and 5) so
that the following values are achieved:

Settings
Modular PCB Conveyor System 6.7.12 Jumper Settings for Conveyor Control TSP 201
274 Service Manual SIPLACE D1/D1i/D2/D2i
6.7.12
6.7.12 Jumper Settings for Conveyor Control TSP 201
Jumper Settings for Conveyor Control TSP 201
See also
6.7.12.2 PCB Handling - Predecessor and Successor Station [ ➙ 275]
6.7.12.3 SIEMENS / SMEMA [ ➙ 276]
6.7.12.4 Single / Dual Conveyor [ ➙ 276]
Values: Move upwards Move down-
wards
Tolerance
Values without lifting table plate as adjustment
aid for single conveyor
~440 ms ~580 ms +/- 20 ms
Values with lifting table plate 500 ms 480 ms +/- 20 ms
Time needed to move lifting table up with lifting table
plate (D4 shown as example)
Checking times in SITEST
► Check the times in the SITEST menu Leiterplatten-
transport:
► Switch the machine on and start the SITEST pro-
gram.
► In the PCB conveyor functions menu (see adjacent
diagram) you can see the travel time for the lifting ta-
ble (from SW 602 upwards).
► Click on Actuate Clamp.
Time needed to move lifting table down with lifting table
plate
► The lifting table will be moved up and the travel time
will be displayed (see diagram).
► Press the Actuate Clamp button again to move the
lifting table downwards and to view the travel time for
the downwards movement.
NOTICE! Move the lifting table plate multiple
times, to check the setting times.
► If malfunctions occur during the downwards move-
ment or if the board is shaken, reduce the lowering
speed accordingly.

Settings
6.7.12 Jumper Settings for Conveyor Control TSP 201 Modular PCB Conveyor System
Service Manual SIPLACE D1/D1i/D2/D2i 275
6.7.12.1
6.7.12.1 Overview
Overview
TSP 201
Legend
6.7.12.2
6.7.12.2 PCB Handling - Predecessor and Successor Station
PCB Handling - Predecessor and Successor Station
1 PCB handling (predecessor /successor
stations)
3 DIP switch for single / dual conveyors
2 Jumper for SIEMENS / SMEMA option
Legend
1. X1 – PCB handling – predecessor station lane 1
2. X2 – PCB handling – successor station lane 1
3. X4 – PCB handling – predecessor station lane 2
4. X5 – PCB handling – successor station lane 2
Connector and interface status display
▪ A = Received
▪ B = Permitted
▪ C = Transmitted
▪ D = Requested