00195376-05_SM_D1_D1i_D2_D2i_EN - 第51页

Service Work 4.1.1 Power Supply Unit Electrical System Service Manual SIPLACE D1/D1i/D2/D2i 51 Primary terminals of transforme r T1 Secondary side of transformer T1 Secondary terminals o f transformer T1 Transfor mer T1 …

100%1 / 280
Service Work
Electrical System 4.1.1 Power Supply Unit
50 Service Manual SIPLACE D1/D1i/D2/D2i
Measuring voltages at main power filter Z1 and electrolytic capacitor C1
The diagram above shows the position of the power supply filter and the electrolytic capacitor C1.
4 main power filters for 36 A 3-phase systems
10 electrolytic capacitors 33000 µF / 63 V
Measuring voltages at transformer T1
Primary side of transformer T1
The transformer can be connected to the following main power supplies:
3 x 230 VAC for the "on-board electrical system" is drawn at terminals 1U5, 1V5 and 1W5. These are
used to supply the PC and the monitor.
Rectifiers Input Output
V1 3 x 140 VAC 200 VDC
V2 150 VDC 150 VDC
V3 3 x 32.5 VAC 40 VDC
V4 3 x 32.5 VAC 40 VDC
V6 3 x 40.7 VAC 48 VDC
V7 3 x 24.4 VAC 24 VDC
NOTICE
Remember to replace the perspex safety panel over rectifier V1, when the measurements
have been completed.
DANGER
RISK OF DEATH BY ELECTRIC SHOCK
Switch the placement system off at the main switch.
Disconnect the placement system from the power supply.
Assembly Terminal Voltages
Main power filter Z1 L1, L2, L3 3 x 204 V~ / 3 x 230 V~ / 3 x 380 V~ / 3 x 400 V~/
3x415V~
Electrolytic capacitor
C1
+ / - 52 VDC
Voltage Terminals
3 x 200-210 V~ (U.S.A) ± 5 %, 50/60 Hz 1U6, 1V6, 1W6
3 x 230 VAC ± 5 %, 50/60 Hz 1U5, 1V5, 1W5
3 x 380 VAC ± 5 %, 50/60 Hz 1U4, 1V4, 1W4
3 x 400 VAC (Europe) ± 5 %, 50/60 Hz 1U3, 1V3, 1W3
3 x 415 VAC ± 5 %, 50/60 Hz 1U1, 1V1, 1W1
Service Work
4.1.1 Power Supply Unit Electrical System
Service Manual SIPLACE D1/D1i/D2/D2i 51
Primary terminals of transformer T1
Secondary side of transformer T1
Secondary terminals of transformer T1
Transformer T1 supplies the following voltages on the secondary side:
3 x 24.4 VAC
3 x 40.7 VAC
Service Work
Electrical System 4.1.1 Power Supply Unit
52 Service Manual SIPLACE D1/D1i/D2/D2i
3 x 8.14 VAC
3 x 32.5 VAC
3 x 32.5 VAC
3 x 24.4 VAC
Terminal panel of the power supply unit
Terminal panel of the power supply unit
T1: 11.1 kVA three-phase transformer
X14: P200 V - screwed connection M6 (+) for supply-
ing the X/Y axis servo amplifier
X15,16,17, EEP: N200 V - screwed connection M8/
M6 (-) for supplying the X/Y axis servo amplifier
X2: To the monitor 1, 2
X3: Box PC
X4: Micro Box PC
X5: Main distributor/subdistributor (regulated voltage)
X6: PCB conveyor
X7: Subdistributor (unregulated voltage)
X8: Axis unit
X10: Main distributor (unregulated voltage)
X12: From/to the main distributor, (control signals,
power supply)
X13: From/to the main distributor, (PCC peripherals)
The pin assignments of the individual plugs are shown in
the detailed circuit diagrams in section 3 "Circuit dia-
grams".