00195376-05_SM_D1_D1i_D2_D2i_EN - 第51页
Service Work 4.1.1 Power Supply Unit Electrical System Service Manual SIPLACE D1/D1i/D2/D2i 51 Primary terminals of transforme r T1 Secondary side of transformer T1 Secondary terminals o f transformer T1 Transfor mer T1 …

Service Work
Electrical System 4.1.1 Power Supply Unit
50 Service Manual SIPLACE D1/D1i/D2/D2i
Measuring voltages at main power filter Z1 and electrolytic capacitor C1
The diagram above shows the position of the power supply filter and the electrolytic capacitor C1.
▪ 4 main power filters for 36 A 3-phase systems
▪ 10 electrolytic capacitors 33000 µF / 63 V
Measuring voltages at transformer T1
Primary side of transformer T1
The transformer can be connected to the following main power supplies:
3 x 230 VAC for the "on-board electrical system" is drawn at terminals 1U5, 1V5 and 1W5. These are
used to supply the PC and the monitor.
Rectifiers Input Output
V1 3 x 140 VAC 200 VDC
V2 150 VDC 150 VDC
V3 3 x 32.5 VAC 40 VDC
V4 3 x 32.5 VAC 40 VDC
V6 3 x 40.7 VAC 48 VDC
V7 3 x 24.4 VAC 24 VDC
NOTICE
► Remember to replace the perspex safety panel over rectifier V1, when the measurements
have been completed.
DANGER
RISK OF DEATH BY ELECTRIC SHOCK
► Switch the placement system off at the main switch.
► Disconnect the placement system from the power supply.
Assembly Terminal Voltages
Main power filter Z1 L1, L2, L3 3 x 204 V~ / 3 x 230 V~ / 3 x 380 V~ / 3 x 400 V~/
3x415V~
Electrolytic capacitor
C1
+ / - 52 VDC
Voltage Terminals
3 x 200-210 V~ (U.S.A) ± 5 %, 50/60 Hz 1U6, 1V6, 1W6
3 x 230 VAC ± 5 %, 50/60 Hz 1U5, 1V5, 1W5
3 x 380 VAC ± 5 %, 50/60 Hz 1U4, 1V4, 1W4
3 x 400 VAC (Europe) ± 5 %, 50/60 Hz 1U3, 1V3, 1W3
3 x 415 VAC ± 5 %, 50/60 Hz 1U1, 1V1, 1W1

Service Work
4.1.1 Power Supply Unit Electrical System
Service Manual SIPLACE D1/D1i/D2/D2i 51
Primary terminals of transformer T1
Secondary side of transformer T1
Secondary terminals of transformer T1
Transformer T1 supplies the following voltages on the secondary side:
▪ 3 x 24.4 VAC
▪ 3 x 40.7 VAC

Service Work
Electrical System 4.1.1 Power Supply Unit
52 Service Manual SIPLACE D1/D1i/D2/D2i
▪ 3 x 8.14 VAC
▪ 3 x 32.5 VAC
▪ 3 x 32.5 VAC
▪ 3 x 24.4 VAC
Terminal panel of the power supply unit
Terminal panel of the power supply unit
▪ T1: 11.1 kVA three-phase transformer
▪ X14: P200 V - screwed connection M6 (+) for supply-
ing the X/Y axis servo amplifier
▪ X15,16,17, EEP: N200 V - screwed connection M8/
M6 (-) for supplying the X/Y axis servo amplifier
▪ X2: To the monitor 1, 2
▪ X3: Box PC
▪ X4: Micro Box PC
▪ X5: Main distributor/subdistributor (regulated voltage)
▪ X6: PCB conveyor
▪ X7: Subdistributor (unregulated voltage)
▪ X8: Axis unit
▪ X10: Main distributor (unregulated voltage)
▪ X12: From/to the main distributor, (control signals,
power supply)
▪ X13: From/to the main distributor, (PCC peripherals)
The pin assignments of the individual plugs are shown in
the detailed circuit diagrams in section 3 "Circuit dia-
grams".