00195376-05_SM_D1_D1i_D2_D2i_EN - 第62页
Service Work Gantries 4.2.2 Replacing the Tensioning Keys [00329478-xx] 62 Service Manual SIPLACE D1/D1i/D2/D2i Elastomeric spri ng (arrangement in D4 shown) Legend ► Loosen the M8x20 hexagon socket-head scr ew in the dr…

Service Work
4.1.10 Replacing the Protective Cover Switch [00335263-XX] Gantries
Service Manual SIPLACE D1/D1i/D2/D2i 61
4.1.10
4.1.10 Replacing the Protective Cover Switch [00335263-XX]
Replacing the Protective Cover Switch [00335263-XX]
Removal/Installation
4.2
4.2 Gantries
Gantries
4.2.1
4.2.1 Replacing the Elastomeric Spring [00301040-XX]
Replacing the Elastomeric Spring [00301040-XX]
Tools and equipment
▪ Set of DIN 911 Allen keys
Parts
▪ Elastomeric spring 25 x 10.5 x 50, [00301040-xx]
Removing the elastomeric spring
► Switch the machine off and secure it to prevent unauthorized reactivation as described in section.
Tools and equipment required
▪ Detailed circuit diagrams for SIPLACE D series [Ger-
man: 00194841-xx] [English: 00194842-xx]
Legend
1. Installation position of cover switch at the input/output
side (when cover is open)
2. Cover switch with connection cable, complete
► Where necessary, dismantle the covers.
► Label the appropriate connections at the sector dis-
tributor.
► Unplug the connection cable.
► Unthread the connection cable as far as the cover
switch (1). Where necessary, dismantle the covers.
► Loosen the screws fastening the cover switch.
► Fit the new cover switch.
► Rethread the connection cable and plug in the elec-
trical connections.
► Close the protective cover and check that the cover
switch engages properly and is actuated.
► Correct the position of the cover switch at the slots.
► Switch the machine on and check that the cover
switch activates the safety circuit, when the protective
cover is opened.
► Fit the covers.
DANGER
POWERFUL MAGNETIC FIELD
► Always follow the special safety instructions when working in the vicinity of powerful mag-
netic fields (see section).

Service Work
Gantries 4.2.2 Replacing the Tensioning Keys [00329478-xx]
62 Service Manual SIPLACE D1/D1i/D2/D2i
Elastomeric spring (arrangement in D4 shown)
Legend
► Loosen the M8x20 hexagon socket-head screw in the drilling in the elastomeric spring.
Installing the elastomeric spring
► Use the M8 x 20 hexagon socket-head screw to fix the elastomeric spring.
Settings
None.
4.2.2
4.2.2 Replacing the Tensioning Keys [00329478-xx]
Replacing the Tensioning Keys [00329478-xx]
Tools and equipment
▪ Set of DIN 911 Allen keys
▪ Belt tension measuring device TSM [00326015-xx]
▪ "Measuring belt tensions" operating instructions
Parts
▪ Tensioning keys [00329478-xx]
▪ Tensioning keys [03044521-xx]
1 Elastomeric spring for X-axis 3 All gantries: elastomeric spring for Y-axis
2 Gantries 1 and 3: elastomeric spring for the
Y-axis
Gantries 2 and 4: bracket instead of elasto-
meric spring

Service Work
4.2.2 Replacing the Tensioning Keys [00329478-xx] Gantries
Service Manual SIPLACE D1/D1i/D2/D2i 63
Removing the tensioning keys
Replacing the tensioning keys (D4 shown as example)
Legend
► Switch the machine off and secure it to prevent unauthorized reactivation as described in section.
► Push the head mount in the direction of the deflection pulley (6).
► To relax the toothed belt (5), proceed as follows:
⇨ Loosen the locknut (11) and
⇨ Turn the hexagon socket-head screw (3) counterclockwise.
Removing the tensioning key, item 1 (synchronizing disk, short)
► Loosen the M4 x 5 hexagon socket-head screw (8).
1 Tensioning keys [00329478-xx] 7 Spacer bolt with Benzing U-clip
2 Tensioning keys [03044521-xx] 8 M4 x 5 hexagon socket-head screw
3 M4 x 35 hexagon socket-head screw for
tensioning the toothed belt
9 Synchronizing disk, short
4 Head mount 10 Synchronizing disk, long
5 Toothed belt for the X-axis 11 Locknut
6 Deflection pulley