00197962-01_2nd_HMI_and_Tower_Light_en - 第25页
Installing a Second Human Machine Interface 2.4.4 Step 4: Connecting the Cables to the Monitor Installing th e HMI Tower Kit Assembly Instructions SIPLACE E 25 2.4.4 2 . 4 . 4 S t e p 4 : C o n n e c t in g t h e C a b l…

Installing a Second Human Machine Interface
Installing the HMI Tower Kit 2.4.3 Step 3: Securing the 17-Inch monitor
24 Assembly Instructions SIPLACE E
► Secure the HMI frame on the inside of the base machine using two ISO 4762 M6x20 screws (1).
► Replace the two ISO 10642 M3x8 cap screws and the bottom cover that you removed earlier.
2.4.3
2.4.3 Step 3: Securing the 17-Inch monitor
Step 3: Securing the 17-Inch monitor
► Secure the 17-inch monitor with USB AS-1707A to the HMI frame kit with four ISO 4762 M4x8 cap
screws (1).

Installing a Second Human Machine Interface
2.4.4 Step 4: Connecting the Cables to the Monitor Installing the HMI Tower Kit
Assembly Instructions SIPLACE E 25
2.4.4
2.4.4 Step 4: Connecting the Cables to the Monitor
Step 4: Connecting the Cables to the Monitor
► Connect the HMI frame top cables to the monitor.

Installing a Second Human Machine Interface
Installing the HMI Tower Kit 2.4.5 Step 5: Connecting the HMI Frame Cables to the Base Machine
26 Assembly Instructions SIPLACE E
2.4.5
2.4.5 Step 5: Connecting the HMI Frame Cables to the Base Machine
Step 5: Connecting the HMI Frame Cables to the Base Machine
► Connect the HMI frame tower light cable [03115364-xx] to –X55 of the HMI LOC cable.
Location 1: Cable, HMI LOC1 (two safety loops) [03110630-xx]
Location 2: Cable, HMI LOC2 (two safety loops) [03110636-xx]
► Connect the HMI frame pushbuttons emergency switch cable [03110726-xx] (1) to –X53 of the HMI
LOC cable:
Location 1: Cable, HMI LOC1 (two safety loops) [03110630-xx]
Location 2: Cable, HMI LOC2 (two safety loops) [03110636-xx]