AltaPail II Bulk Melters Product Manual - 第113页

Advanced Software Me lter Configuration 7 -27 Part 1121836_03 E 1 1/2014 Nordson Corporation Configuring Password Protectio n By default, pas sword protection is disabled. NOTE: Refer to Tab le 7-4 for an e xplanation of…

100%1 / 230
Advanced Software Melter Configuration
7-26
Part 1121836_03
E 11/2014 Nordson Corporation
3. Do the following to continue.
Touch Description
Brightness/Contrast Enhance the visibility and readability of the
touchscreen displays.
Screen Saver Delay The amount of time (default 5 minutes) of no user
interaction with the touchscreen before the screen
saver appears.
The screen saver only displays the melter status
and its corresponding color. To extend the lifespan
of the touchscreen itself, the brightness and
contrast are reduced from its current settings to
30%
Touch anywhere on the screen to access the
Operator Display.
Calibrate Screen Allows you to improve the accuracy of your
interaction with the touchscreen.
Touch the
+
symbol to calibrate the touchscreen.
Wipe Display Locks the screen for 30 seconds, allowing you to
clear dust from the touchscreen without touching a
button and accidentally changing a setting.
4. Touch Done.
Advanced Software Melter Configuration
7-27
Part 1121836_03
E 11/2014 Nordson Corporation
Configuring Password Protection
By default, password protection is disabled.
NOTE: Refer to Table 7-4 for an explanation of each security level.
The following are default password level numeric codes:
Level # Default Code Notes
1 1000
S
Cannot start with the number 0 (zero).
S
Can be one up to five numbers long.
S
The largest 5 digit number is 65535.
S
Each
level
must
have
a
unique
numeric
code.
2 2000
3 3000
System
Done
Home
Formats/Units
Date/Time
Password
Display
Service Interval Administration
Scheduler Language
03/20/2014 4:40PM
500 Hours
Password
Done
Home
Create/Modify
Timeout
Set Security Level
5 min.
1. From the Home Display touch
Master
Controls
2. Touch System, then Password.
3. Do the following to continue. When finished, touch Done.
Touch Description
Create/Modify Modify the default numeric password code for each
level.
Timeout Enter the amount of time (the default is 10 minutes)
the selected password protection becomes active
after no user interaction with the touchscreen.
Set Security Level Refer to Table 7-4 for an explanation of each
security level.
Advanced Software Melter Configuration
7-28
Part 1121836_03
E 11/2014 Nordson Corporation
Table 7-4
Security level details
Security
Level
Functions Enabled High Medium Low
3 Application names (temperature channels and pumps
Controlled system heating rate temperature
Switch between °C, °F
Switch between bar, psi, kPa
Temperature channel settings (PID control mode)
Maximum temperature set point
Assign standard I/O inputs for application groups
Seven-day clock settings: (delete/edit schedule, copy schedule)
Motor enables from control panel / control panel AND standard I/O
Gear-to-line signal: Analog/frequency, voltage/current
Speed control / Line speed for min./max. pump speed/pressure
Threshold switch
Restore default settings
Melter configuration
Configuration code input (Local mode / field bus mode)
Customer setup (recipes / application names)
Service interval
System ready-delay setup
Password setup
2 Under-temperature/over-temperature warnings/faults
Standby values (setback delta and duration)
Automatic enter standby
Temperature channel enabled/disabled
Changing pump modes (manual and gear-to-line)
1 Temperature set point
Individual motor enable
Speed set point
Min. and max. pump speed/pressure (in gear-to-line mode)
NOTE: The table indicates the following:
S
High Security includes levels 1, 2 and 3
S
Medium Security includes levels 2 and 3
S
Low Security includes only level 3