Advanced Software Melter Configuration
7-49
Part 1121836_03
E 11/2014 Nordson Corporation
Default User Settings and Ranges
The following details default settings and ranges for user definable melter,
temperature, pump and melter settings.
Temperature Settings
Setting Default Range/Option
Temperature Limits
Over Temp: 15_C (25_F) Minimum: 5_C (10_F)
Maximum: 60_C (110_F)
Under Temp: 25_C (50_F) Minimum: 5_C (10_F)
Maximum: 60_C (110_F)
Ready Delay 60 minutes Minimum: 0 minutes
Maximum: 60 minutes
Automatic Standby Disabled Enabled
Disabled
Auto Standby Start Time 0 minutes Minimum: 0 minutes
Maximum: 1,440 minutes
Auto Heaters Off Time in Auto
Standby Mode
60 minutes Minimum: 0 minutes
Maximum: 1,440 minutes
Auto Exit Standby Time Disabled Enabled
Disabled
Auto Exit Heaters Off Time in
Auto Manual Mode
0 minutes Minimum: 0 minutes
Maximum: 180 minutes
Standby Temp 50_C (100_F) Minimum: 5_C (10_F)
Maximum: 60_C (110_F)
For Melters:
7407039, 7407040, 7407041. 7407042, 7407668 and 7407669
Setting Default Range/Option
External Zones Set Point 176_C (350_F) Minimum: 40_C (100_F)
Maximum: 176_C (350_F)
Internal Zones Set Point 176_C (350_F) Minimum: 40_C (100_F)
Maximum: 176_C (350_F)
Global Set Point 176_C (350_F) Minimum: 40_C (100_F)
Maximum: 176_C (350_F)
For Melters:
7407664, 7407665, 7407666, 7407667, 7407670 and 7407671
Setting Default Range/Option
External Zones Set Point 232_C (450_F) Minimum: 40_C (100_F)
Maximum: 232_C (450_F)
Internal Zones Set Point 232_C (450_F) Minimum: 40_C (100_F)
Maximum: 232_C (450_F)
Global Set Point 232_C (450_F) Minimum: 40_C (100_F)
Maximum: 232_C (450_F)
Advanced Software Melter Configuration
7-50
Part 1121836_03
E 11/2014 Nordson Corporation
Pump Settings
Setting Default Range/Option
Operation Mode Manual Manual
Gear-to-Line
* Pressure Control
* Flow Control
NOTE: *Requires additional
hardware
Pump RPM 0 Minimum: 0 RPM
Maximum: 94 RPM
Auto Pump Off Off
On
Remote Control None set Off
On
Advanced Software Melter Configuration
7-51
Part 1121836_03
E 11/2014 Nordson Corporation
Melter Settings
Setting Default Range/Option
Service Interval 500 hours Minimum: 0 hours
Maximum: 8760 hours
Scheduler No events defined Minimum: 2 events per day
Maximum: 12 events per day
Password Protection No Password Protection High
Medium
Low
No Password Protection
Password Level Codes Level 1: 1000
Level 2: 2000
Level 3: 3000
Minimum: 1
Maximum: 65535
NOTE: Code levels must be
unique.
Password Timeout 1 minute Minimum: 1
Maximum: 60
Display Brightness/Contrast 75% | 75% Minimum: 30%
Maximum: 100%
Display Screen Saver Delay 1 minute Minimum: 1 minute
Maximum: 120 minutes
RTD Options NI120 NI120
Lockout Communications Off Off
On
Inputs/Outputs
Inputs Inputs:
#1: Automatic Standby
#2: Standby
#3: Heater Control
#4: External Zone # A/B
Disabled
Standby
Heater Control
Pump (Control)
External Zone # A/B
Automatic Standby (Available
only for Input #1
Outputs Outputs:
#1: Ready
#2: Fault
#3: Tank Low
Disabled
Ready
Ready-Pump On
Fault
Tank Low
Alert
Service Reminder