AltaPail II Bulk Melters Product Manual - 第138页

Maintenanc e 8-1 Part 1121836_03 E 11/2014 Nordson Corporation Section 8 Maintena nce WARNING! Allow only qual ified personnel to p erform the following ta sks. Follow the safety instructions in th is document and all ot…

100%1 / 230
Advanced Software Melter Configuration
7-51
Part 1121836_03
E 11/2014 Nordson Corporation
Melter Settings
Setting Default Range/Option
Service Interval 500 hours Minimum: 0 hours
Maximum: 8760 hours
Scheduler No events defined Minimum: 2 events per day
Maximum: 12 events per day
Password Protection No Password Protection High
Medium
Low
No Password Protection
Password Level Codes Level 1: 1000
Level 2: 2000
Level 3: 3000
Minimum: 1
Maximum: 65535
NOTE: Code levels must be
unique.
Password Timeout 1 minute Minimum: 1
Maximum: 60
Display Brightness/Contrast 75% | 75% Minimum: 30%
Maximum: 100%
Display Screen Saver Delay 1 minute Minimum: 1 minute
Maximum: 120 minutes
RTD Options NI120 NI120
Lockout Communications Off Off
On
Inputs/Outputs
Inputs Inputs:
#1: Automatic Standby
#2: Standby
#3: Heater Control
#4: External Zone # A/B
Disabled
Standby
Heater Control
Pump (Control)
External Zone # A/B
Automatic Standby (Available
only for Input #1
Outputs Outputs:
#1: Ready
#2: Fault
#3: Tank Low
Disabled
Ready
Ready-Pump On
Fault
Tank Low
Alert
Service Reminder
Maintenance
8-1
Part 1121836_03
E 11/2014 Nordson Corporation
Section 8
Maintenance
WARNING! Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
NOTE: Maintenance is an important preventive measure for maintaining
operating safety and extending the service life of the unit. It should not be
neglected under any circumstances.
Risk of Burns
Some maintenance work can only be done when the bulk melter is heated
up.
WARNING: Hot! Risk of burns. Wear safety goggles and heat-protective
gloves.
Relieving Pressure
WARNING: System and material pressurized. Relieve bulk melter pressure
before disconnecting pressurized components (e.g. hoses, pressure
sensors). Failure to observe can result in serious burns.
1. Switch the pump off.
2. Set selector Raise/lower platen to 0.
3. Place a container under the nozzle(s) of the applicator/assembly
handgun.
4. Applicators: Activate the solenoid valve(s) electrically or manually; or, pull
the trigger of the assembly handgun. Repeat this procedure until no more
material flows out.
5. Re-use the material or properly dispose of it according to local
regulations.
Maintenance
8-2
Part 1121836_03
E 11/2014 Nordson Corporation
Important when Using Cleaning Agents
S
Use only a cleaning agent recommended by the hot melt material
manufacturer. Observe the Material Safety Data Sheet for the cleaning
agent.
S
Properly dispose of cleaning agent according to local regulations.
Processing Materials
Before using, read the included EU safety data sheet.
Designation Order number Use
High temperature grease
To
be
applied
to
O-rings
and
threads
NOTE: The grease may not be
mixed with other lubricants.
Oily/greasy parts must be cleaned
before
application.
S
Can 10 g
P/N 394769
S
Tube 250 g
P/N 783959
S
Cartridge 400 g
P/N 402238
Grease Centoplex H0
S
1 kg
P/N 285600
Lubricating platen sealing ring
Sealing paste Stucarit 203
Applied
to
sealing
surfaces
S
Tube 100 ml
P/N 255369
Temperature-resistant
adhesive Loctite 640
Secures
screw
connections
S
50 ml
P/N 230359
Heat transfer compound
To
improve
heat
conducting
of
temperature sensors
S
500 g
P/N 257326