AltaPail II Bulk Melters Product Manual - 第142页

Maintenanc e 8-5 Part 1121836_03 E 11/2014 Nordson Corporation External Cleaning External clea ning prevents pollution cre ated by production from causing bulk melter malfunc tions. CAUTION: O bserve th e unit’s Deg ree …

100%1 / 230
Maintenance
8-4
Part 1121836_03
E 11/2014 Nordson Corporation
Initial Maintenance
Heating and cooling that occur during daily operation can cause screwed
parts to loosen, resulting in leakage.
Re-tighten the following components with a torque wrench:
Component Torque
Note
Example Pos. Designation [Nm] [lbin]
5
4
1
2
1 Plug 20 176 A
2 Hose fitting 25 220 A
4 Pump: Fixing screws 25 220 A, B
5 Safety valve 15 133 A
NOTE A: Re-tighten while the material is still soft (approx. 70 ° C/158 ° F, depending on the material)
B: Re-tighten crosswise
Maintenance
8-5
Part 1121836_03
E 11/2014 Nordson Corporation
External Cleaning
External cleaning prevents pollution created by production from causing bulk
melter malfunctions.
CAUTION: Observe the unit’s Degree of Protection when cleaning. Refer to
page 12-3, Electrical Data.
CAUTION: Do not damage or remove safety labels. Damaged or removed
safety labels must be replaced by new ones.
Remove material residue only with a cleaning agent recommended by the
material supplier. Heat with an air heater if necessary.
Remove dust, flakes etc. with a vacuum cleaner or a soft cloth.
Visual Inspection for External Damage
WARNING! When damaged parts endanger the operating safety and/or the
safety of personnel, switch off the bulk melter and have the damaged parts
replaced by qualified personnel. Use only original Nordson spare parts.
Changing Type of Material
NOTE: Before changing the material type, determine whether the old and
new material can be mixed.
S
May be mixed: Remaining old material can be flushed out using the new
material.
S
May not be mixed: Purge thoroughly and clean melting plate with a
cleaning agent recommended by the material manufacturer. Refer to
page 8-6, Cleaning Melting Plate.
NOTE: Properly dispose of the old material according to local regulations.
Maintenance
8-6
Part 1121836_03
E 11/2014 Nordson Corporation
Purging with Cleaning Agent
Place a container of cleaning agent in the bulk melter to purge. Then feed the
cleaning agent until it comes out free of material residue.
CAUTION: Use only a cleaning agent recommended by the hot melt
material manufacturer. Observe the Material Safety Data Sheet for the
cleaning agent.
Before starting production again, flush out residue of the cleaning agent
using the new material.
NOTE: Properly dispose of cleaning agent according to local regulations.
Cleaning Melting Plate
The melting plate is standardly release-coated. This makes it easy to clean.
Cooled material can usually be pulled off of the melting plate; if necessary,
first heat to approx. 60 ° C / 140 ° F.
CAUTION: Do not use hard or metallic tools to clean. Do not use wire
brushes! This could damage the release coating. Use only soft aids
(wooden or PTFE spatula or soft brush).