AltaPail II Bulk Melters Product Manual - 第146页
1 Maintenanc e 8-9 Part 1121836_03 E 11/2014 Nordson Corporation Gear P ump Checking for Leakage Variseals a re fixed in pla ce on the pump with a flange (1). If material escapes along the shaft, the pump shaft s eal mus…

Maintenance
8-8
Part 1121836_03
E 11/2014 Nordson Corporation
Motor / Gear Box
Change lubricant
Observe when changing lubricant:
S
Drain lubricant when warm
S
Use only the stated lubricant or one that has proven to be equivalent.
Using any other lubricant can result in premature wear and/or damage to
the gear box
S
Properly dispose of the old lubricant according to local regulations.
Remove gear box from the motor to change lubricant. Wash out casing with
suitable cleaning agent and remove lubricant residue.
Lubricant Changing Interval
When lubricant temperature is below 100° C / 212° F:
Every 15000 hours of operation or at least every 2 to 3 years.
Capacity
The lubricant quantity is indicated on the ID plate.
NOTE: Never mix different types of lubricants.
Lubricant Selection
Lubricant manufacturer Mineral oil CLP 220
AGIP Blasia 220
ARAL Degol BMB 220 or Degol BG 220
BP Energol GR-XP 220
DEA Falcon CLP 220
ESSO Spartan EP 220 or GP 90
KLÜBER Klüberoil GEM 1-220
OPTIMOL Optigear 220
SHELL Omala Oil 220
TEXACO Geartex EP-A SAE 85 W-90

1
Maintenance
8-9
Part 1121836_03
E 11/2014 Nordson Corporation
Gear Pump
Checking for Leakage
Variseals are fixed in place on the pump with a flange (1). If material escapes
along the shaft, the pump shaft seal must be replaced.
NOTE: A special assembly tool is needed for replacement. Refer to the
separate document Parts List. However, Nordson recommends replacing the
pump and sending the old one in to be repaired. Refer to page 10-2,
Replacing Gear Pump.

Maintenance
8-10
Part 1121836_03
E 11/2014 Nordson Corporation
This page intentionally left blank.