Hardware Operation 4-7 Part 1121836_03 E 11/2014 Nordson Corporation Setting Platen Pressure S Increase pressure for high-viscosity (ropy) mate rials S Decrease pres sure for low-viscosity (liquid) materials. NOTE: The d…

Hardware Operation
4-6
Part 1121836_03
E 11/2014 Nordson Corporation
Purging Bulk Melter
You must remove or purge this material before you can use the melter in a
production environment.
Test material was used for testing prior to shipping the melter. There may be
some of the test material on the melting plate and in the pump. Place a
container under the applicator and run the pump until you no longer see the
test material.

Hardware Operation
4-7
Part 1121836_03
E 11/2014 Nordson Corporation
Setting Platen Pressure
S
Increase pressure for high-viscosity (ropy) materials
S
Decrease pressure for low-viscosity (liquid) materials.
NOTE: The default pressure is 6 bar / 0.6 MPa / 87 psi

Hardware Operation
4-8
Part 1121836_03
E 11/2014 Nordson Corporation
Setting Material Pressure
Pressure Control Actuator
Mechanical control with
manually adjustable pressure
control valve (1)
1
+
-