AltaPail II Bulk Melters Product Manual - 第88页

Advanced Software M elter Configuration 7 -2 Part 1121836_03 E 1 1/2014 Nordson Corporation Advanced Tempe rature Settings The following se ctions detail t he following: S Defining a global set point temperatu re (all zo…

100%1 / 230
Advanced Software Melter Configuration
7-1
Part 1121836_03
E 11/2014 Nordson Corporation
Section 7
Advanced Software Melter Configuration
WARNING! Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
Overview
The melter is shipped from the factory with most temperature, pump and
melter (system) settings pre-configured and ready to use. However, there are
some settings that you must configure and fine-tune to best fit your
manufacturing process.
Accessing the Settings Screen
Done
Scheduler
Pump ControlHeater Control
Standby
Settings System
Master Controls
Scheduler: Off
Pump: OnHeaters: On
Standby: Off
Settings
Done
Home
Temperature
Input
Ready Delay
Standby
Output Pump
S
From the Home Display touch
Master
Controls
then touch Settings.
Advanced Software Melter Configuration
7-2
Part 1121836_03
E 11/2014 Nordson Corporation
Advanced Temperature Settings
The following sections detail the following:
S
Defining a global set point temperature (all zones)
S
Defining over and under temperature limits
S
Defining a set point temperature only for all hoses
S
Defining a set point temperature only for all applicators
Accessing Temperature Settings
Settings
Done
Home
Temperature
Input
Ready Delay
Standby
Output Pump
Temperature
Done
Home
Global Set Point
Temperature Limits
Set Point - All Applicators
Set Point - All Hoses
1. From the Home Display touch
Master
Controls
2. Touch Settings, then Temperature.
Refer to the following sections for more information.
Advanced Software Melter Configuration
7-3
Part 1121836_03
E 11/2014 Nordson Corporation
Defining a Global Set Point Temperature
Use global set point temperature to configure all zones (platen, hoses
handguns/applicators with a uniform set point temperature.
For Melters:
7407039, 7407040, 7407041. 7407042, 7407668 and 7407669
Default Minimum Maximum
176°C (350°F) 40°C (100°F) 176°C (350°F)
For Melters:
7407664, 7407665, 7407666, 7407667, 7407670 and 7407671
Default Minimum Maximum
232°C (450°F) 40°C (100°F) 232°C (450°F)
NOTE: Defining a global set point temperature enables previously disabled
zones.
Temperature
Done
Home
Global Set Point
Temperature Limits
Set Point - All Applicators
Set Point - All Hoses
Done
Cancel
7 8 9
4 5 6
1 2 3
0
Global Set Point Temperature
176
Home
C
o
1. From the Home Display touch
Master
Controls
2. Touch Settings, then Temperature.
3. Touch Global Set Point and enter the global set point temperature you
want for all available zones.
4. Touch Done.