GD450 说明书(中英文版) - 第74页
- 74 - 第五章 报警处置 Chapter 5 A l arm dis posal 5.1 机器报警项目 The alarm items 1 气压不足报警 Insufficient air pressure 2 紧急按钮按下时报警 The emergent button has been pressed 3 清洗装置不在原点报警 The cleaning device is not at its positi on 4 伺服马达驱动…

- 73 -
图 4-18(版本信息) Pix 4-18(version information)
9: : 中英切换按钮。单击该按钮将中文界面切换成英文;
: Chinese and English shift. The Chinese interface will be shifted to
English interface by clicking this button.

- 74 -
第五章 报警处置
Chapter 5 Alarm disposal
5.1 机器报警项目 The alarm items
1 气压不足报警
Insufficient air pressure
2 紧急按钮按下时报警
The emergent button has been pressed
3 清洗装置不在原点报警
The cleaning device is not at its position
4 伺服马达驱动器报警
Servo motor driver alarms
5 门开关警示
The alarm of the open/close of door
6 清洗纸已经用完警示
The cleaning papers have been used up.
7 清洗液用完警示
The cleaning liquid has been used up.
8 运输超时,请按复位键警示
Please press reset button when the transmission is overtime.
5.2 报警项目解释及处置方法 The explanation and disposal of the alarm item
1 气压不足报警,当压缩空气的压力达不到我们设置的最低值或者超出最高值时,软件
会弹出报警对话框,同时三色灯显示红色,蜂鸣器呜呜作响。如图 5-1 所示:
When the air pressure is insufficient, the system will alarm. If the compressed air
pressure can not reach the Min value or above Max value which are set-up before, the
software will display the alarm dialogue box and the tricolor light will show the red color and
the buzzer will make whining noise. See pix 5-1.

- 75 -
图 5-1(气压不足报警)
Pix 5-1 (alarm when there is not insufficient air pressure)
通常有三种可能会造成该状况,请按照下面的介绍使用排除法依次解除故障,直到机器正
常工作。
Usually there are three possibilities which will lead this situation. Please deal with the
faults in turn with exclusive method according to the following introductions until the
equipment can work normally.
A 气动三联件上的“三通残压阀门”处在关闭状态
The three way residual pressure valve on the pneumatic FRL is at the closed.
请检查该阀门是否处在关闭状态,如是关闭的,请开启。如是开启的,请参照 B 介
绍寻找原因;