Notes: Chapter 6 6.2 Measuring Parts Camera Proper Data and Adjustment Edition 1.1 6-10 QP-132 Level 3 T utorial

100%1 / 136
6.2.7 Lighting
Note: VP version : V2.96 or after
1. Attach 0.7 diameter nozzles to all holders.
2. Select program PRODUCT_1005_QP1_D.
3. Press [SET] [MANUAL] [NOZZLE] [NOZZLE COND] [In
turn meas] or [Simult meas] [EXECUTE] Enter Starting PM No. and
the Last PM No. START.
4. Press [RESULTS] [B_LIGHT DATA] to check the brightness.
Gray scale value : 170 ± 20
5. If the gray scale value is out of range, perform the following in order:
* Replace the nozzles.
* Replace the UV lamp.
* Replace the camera.
Chapter 6
6.2 Measuring Parts Camera Proper Data and Adjustment
Edition 1.1 6-9 QP-132 Level 3 Tutorial
Notes:
Chapter 6
6.2 Measuring Parts Camera Proper Data and Adjustment
Edition 1.1 6-10 QP-132 Level 3 Tutorial
6.3 Training Evaluation
Circle the most appropriate answer from the list below.
(1) If the gray scale value of back light nozzle is out of range:
a. replace the Nozzle and UV lamp.
b. replace the Camera.
c. Both a and b.
(2) To adjust Parts Camera, move the camera:
a up.
b. down.
c. Does not matter.
(3) To focus the parts camera:
a. the lowest positioned nozzle is used.
b. the highest positioned nozzle is used.
c. the average positioned nozzle is used.
(4) If parts camera resolution is too high:
a. raise the camera.
b. lower the camera.
c. lower the nozzle holder.
(5) Proper data nozzle offset is:
a. the distance of nozzle B, C, D from A
b. the distance between nozzle A, B, C and D
c the distance of nozzle B, C, D from Q-axis
Chapter 6 6.3 Training Evaluation
Edition 1.0 6-11 QP-132 Level 3 Tutorial