QP132三级参考手册.pdf.pdf - 第93页

Chapter 7 PFU

100%1 / 136
Notes:
Chapter 6 6.3 Training Evaluation
Edition 1.0 6-12 QP-132 Level 3 Tutorial
Chapter 7
PFU
7.1 Measuring PFU Proper Data and
Adjustment
Required Jigs: Dummy Clamp Jig (Z9314CGQJ0161)
Feeder Jig (ACGPJ9070)
Nozzle Jig (ACGPJ9021)
7.1.1 PFU Clamper Adjustment
Speed Controller
1. Adjust the speed controllers located on the left bottom door on the front
side of the machine.
PFU Clamp: 2 turns from the fully closed position.
PFU Unclamp: 1.5 turns from the fully closed position.
2. Remove the bottom cover of the clamper and press [SET] [MANUAL]
[I/O] [STANDARD I/O] [OUTPUT] and select I/O to unclamp.
3. Move both sensors and check the input signal.
Note: Both left and right clamper cylinder sensors need to be ON when clamped.
4. Move the cylinder forward end sensor positions one by one to find the
position.
[IN-Side] [OUT-Side]
X034 PFU1 CLP Y040 PFU1 CLAMP
X035 PFU1 UNCLP Y041 PFU1 UNCLAMP
X036 PFU2 CLP Y042 PFU2 CLAMP
:: : :
X03B PFU4 UNCLP Y047 PFU4 UNCLAMP
5. Clamp dummy clamp jig (Z9314CGQJ0161) using I/O.
Chapter 7 7.1 Measuring PFU Proper Data and Adjustment
Edition 1.1 7-1 QP-132 Level 3 Tutorial