00193802-01 - 第72页

3 Technical data User Manual SIP LACE CF 3.3 Electrical and pneumat ic connection points S oftware version SR.101.xx 06/2003 US E dition 72 3.3 Electrical and pneuma tic connection point s 3 Fig. 3.3 - 1 Electrical and p…

100%1 / 188
User Manual SIPLACE CF 3 Technical data
Software version SR.101.xx 06/2003 US Edition 3.2 The line concept
71
3.2 The line concept
3.2.1 Overview
Up to 5 placement machines from the SIPLACE Compact families can be linked to form a line.
3.2.2 Technical data – line concept
3
System SIPLACE placement lines
Modules SIPLACE CS, SIPLACE CF
Peripherals Input/output stations
Screen printers
Soldering ovens
Inspection stations, etc.
Component range From 0201 to 18.7 mm x 18.7 mm (CS)
From 0201 to 55 mm x 55 mm (CF)
PCB conveyor Automatic width adjustment
PCB format (length x width) 50 mm x 50 mm to 508 mm x 460 mm
(2" x 2" to 20" to 18")
Placement rate Depends how modules are connected in series
Line software SIPLACE C Pro
Space required 4 m² / module
3 Technical data User Manual SIPLACE CF
3.3 Electrical and pneumatic connection points Software version SR.101.xx 06/2003 US Edition
72
3.3 Electrical and pneumatic connection points
3
Fig. 3.3 - 1 Electrical and pneumatic connection points on the placement system- part 1
(1) Compressed air unit
(2) Connection for compressed air line
(3) Main power filter Z1
(4) Hole for power cable
(5) Service socket
(6) Compressed air connection for component trolleys
(7) Power supply connection for component trolley
(8) Communications connection for component trolley
(9) Communications connection for waffle-pack changer
(10) Power supply connection for waffle-pack changer
User Manual SIPLACE CF 3 Technical data
Software version SR.101.xx 06/2003 US Edition 3.3 Electrical and pneumatic connection points
73
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury! 3
Fig. 3.3 - 2 Electrical and pneumatic connection points on the placement system- part 2
(1) main power switch
(2) Power supply connection for component trolley
(3) communications connection for component trolley
(4) LAN connection (RJ45) in the control unit
WARNING
The placement system is supplied with 3 x 400 V~ or 3 x 208 V~ US version) ± 5%, 50/60 Hz
main power voltage. This means that some parts of the system carry potentially lethal voltages
- even when switched off at the main switch. Incorrect handling of the placement machine can
therefore result in death or severe injury or considerable damage to equipment. 3