00193802-01 - 第74页
3 Technical data User Manual SIP LACE CF 3.4 Technical data – ratings Software version SR. 101.xx 06/2003 US Edition 74 3.4 T echnical da t a – r atings 3.4.1 T echnical dat a – elec trical ra tings 3 3.4.2 T echn ical d…

User Manual SIPLACE CF 3 Technical data
Software version SR.101.xx 06/2003 US Edition 3.3 Electrical and pneumatic connection points
73
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury! 3
Fig. 3.3 - 2 Electrical and pneumatic connection points on the placement system- part 2
(1) main power switch
(2) Power supply connection for component trolley
(3) communications connection for component trolley
(4) LAN connection (RJ45) in the control unit
WARNING
The placement system is supplied with 3 x 400 V~ or 3 x 208 V~ US version) ± 5%, 50/60 Hz
main power voltage. This means that some parts of the system carry potentially lethal voltages
- even when switched off at the main switch. Incorrect handling of the placement machine can
therefore result in death or severe injury or considerable damage to equipment. 3

3 Technical data User Manual SIPLACE CF
3.4 Technical data – ratings Software version SR.101.xx 06/2003 US Edition
74
3.4 Technical data – ratings
3.4.1 Technical data – electrical ratings
3
3.4.2 Technical data – compressed air supply
3
3.4.3 Technical data – compressed air specification
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1)
3.4.4 Technical data – noise emissions
3
3.4.5 Technical data – permissible ambient factors
3
Supply voltage 3 x 400 VAC ± 5 %; 50/60 Hz (Europe)
3 x 208 VAC ± 5 %; 50/60 Hz (U.S.A.)
3 x 200 VAC ± 5 %; 50/60 Hz (Japan)
Fuses 3 x 16 A (3 x 400 VAC, 3 x 208 VAC, 3 x 200 VAC)
Total connected load 5 kVA
Total power 1.9 kW
Power failure Max. 20 msec
Compressed air pressure Min. 0.55 MPa (5.5 bar) to 1.0 MPa (10 bar), ½"-connection
Compressed air consumption 400 Nl/min.
Operating pressure Set to 0.52 MPa (5.2 bar)
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint +3°
Max. noise emissions 74dB(A)
Room temperature Between 15°C and 35°C
Atmospheric humidity 30 to 80%
(but no higher than 45% on average in order to prevent any
possibility of condensation on the machine).

User Manual SIPLACE CF 3 Technical data
Software version SR.101.xx 06/2003 US Edition 3.5 Dimensions and weight of the placement machine
75
3.5 Dimensions and weight of the placement machine
3.5.1 Dimensions of the placement machine
3
Fig. 3.5 - 1 Dimensions of the placement system in millimeters