7 Monthly maintenance jobs SIPLACE D3 08/2008 US Edition 28 7 Monthly maintenance jobs 7

100%1 / 98
SIPLACE D3 6 Weekly maintenance jobs
08/2008 US Edition
27
Empty the component drawer or flap of the 8 mm S feeder modules 6
: Unplug the 8 mm S feeder and lift it off the component table.
6
a Remove loose components from the changeover table with a brush or using the vacuum
cleaner.
s Empty the compo
nent drawer of the 2x8 mm S feeder module (if present).
d Open the flap of the 3x8 mm S feeder module (if present) and remove the components.
6
f Wipe the base of the feeder module to remove any dirt.
6
g Cut off the used tape so that it is flush with the feeder.
: Return the feeder modules to their original (correct) locations.
6
Make sure that the feeder is seated firmly on the component table and is inserted at the right po-
sition. 6
6
6
6
: Close the protective cover.
: Repeat these tasks for the other locations.
6
6
7 Monthly maintenance jobs SIPLACE D3
08/2008 US Edition
28
7 Monthly maintenance jobs
7
SIPLACE D3 7 Monthly maintenance jobs
08/2008 US Edition
29
7
You will need for the monthly maintenance jobs: 7
Laboratory gloves
Lint-free cloths
Lens cloth
Lint-free cottonwool buds
SIPLACE cleaning tissue
Ethyl alcohol
Set of cleaned sleeves (new set, if required)
Set of cleaned and lightly greased
valve p
lungers (new, if required).
7
7
Collect&Place 12 / 6 placement heads 7
Replace the sleeves and valve plungers 7
: Return the nozzles of the Collect&Place head to the nozzle changer.
a Open the protective cover.
7
Do not hold the sleeves in your bare hands. Wear laboratory gloves when carrying out any main-
tenance work on the sleeve. 7
7
This will avoid dirtying the glass disk and the friction wheel unnecessarily, which could lead to
faults (counting errors and overshooting). 7
7
s Remove the sleeves from the head.
Pull the sleeves out as shown in the diagram. 7
7
7
d Place them in the container provided.
: Step the star forward until all the sleeves have been removed.
7