00195094-0202-MM-D3_EN - 第73页

SIPLACE D3 10 Annual maintenance work 08/2008 US Edition 73 Check the protective covers 10 : Open the protective cove rs. 10 a Pull the protective covers down appr ox. 30 cm and then release them. Replace the gas springs…

100%1 / 98
10 Annual maintenance work SIPLACE D3
08/2008 US Edition
72
10
SIPLACE D3 10 Annual maintenance work
08/2008 US Edition
73
Check the protective covers 10
: Open the protective covers.
10
a Pull the protective covers down approx. 30 cm and then release them.
Replace the gas springs if the covers do not open fully once mo
re and there is a gap (approx.
20 mm) in the top position.
10
s Wipe the sliding surfaces of the gas springs clean with a lint-free cloth.
There should be no oil visible on the piston.
10
: Close the protective covers.
10
10
Clean the protective covers 10
10
The choice of cleaning agent for the protective covers must be made with particular care so as not
to damage the ESD coating on the protective covers. 10
10
: Check the protective covers for dirt.
: Clean them with a dry, lint-free cloth, if required.
If it is very
dirty, use a lint-free cloth and a small amou
nt of a neutral or weak alkaline cleaning
agent.
10
This must NOT be 10
acidic or strong alkaline,
contain ketones, esters, aromatics, halogenate
d hydrocar
bons, etheric oils or similar.
10
Apply as little pressure as possible when cleaning the protective covers to avoid damaging the
ESD coating. 10
10
: After cleaning, wipe over with fresh water.
10
10
10 Annual maintenance work SIPLACE D3
08/2008 US Edition
74
10