80S-2080F480F4-680F5 User’s Manual - 第267页

SIPLACE 80S-2 0/F4/F4-6/F5 User’s Manual 5 Vision Functions Edition 03/98 from Software Version SR.404.xx 5.5 Teach Fi du cial Line engi neer 5 - 46 Menu Op tions ’T each fidu cial’, Par t 2 ’Test fiduci al’ menu ESC Yes…

100%1 / 744
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.5 Teach Fiducial
Line engineer 5 - 45
7
Vi
s
Menu Options ’Teach Fiducial’, Part 1
Menu ’Main view’
Fiducial
is restored
Main view Setup Errors PCB transport 1
Gantry 1
functions
Gantry 2 functions
(80S only)
Feeders
Teach
fiducial
Test
component
Save
fiducial
OK
Yes
OK
Fiducial
is saved
No
Cancel
Option box
’Save fiducial’
Fiducial
processed?
Main view Select
fiducial
Teach
fiducial
’Teach fiducial menu option
Select
fiducial
’Select fiducial’ menu
Select fiducial
number
A
Load
fiducial
Define
new fiducial
Select
teach gantry:
Gantry 1
Gantry 2 (for 80S
machine only)
’New fiducial’
input box
Change
fiducial name
Change
fiducial name
Save
fiducial
Cancel
ESC
Teach
fiducial
’Teach fiducialmenu
A
Low
resolution
Video image
Change template
field
Upon any modification of
the search area a teach
message is prompted,
uniqueness value
is displayed
Fiducial
loaded or
tought?
’Select fiducial’
menu
No
Yes
Standard
values
Search
area
Medium
resolution
High
resolution
Video image
Position camera and
change search area
Upon any modification of
the search area a teach
message is prompted,
uniqueness value
is displayed
Video image
Position
camera
Teach message with
standard values
Output of
uniqueness
ESCESC
Change search area
’Change fiducial name’
input box
Fiducial
loaded or
tought?
No
Yes
Contrast
sensitivity
Test
fiducial
PCB transport 2 SITEST GEM
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.5 Teach Fiducial
Line engineer 5 - 46
Menu Options ’Teach fiducial’, Part 2
’Test fiducial’ menu
ESC
Yes
Test fiducial
Fiducial
loaded or
tought?
A
’Select fiducial
menu
ESC
Center TestPCB to center conveyorMove X/Y axes PCB to output conveyor
Positioning Fiducial
Video image
Position
camera
PCB transport
Video image
Define
template
window
(hor./vert.)
Video image
Triggering
measurement
sequence; output
fiducial quality
No
Return
(Save)
’Contrast sensitivity’ menu
Accept
(Save programmed
values)
Yes
Contrast sensitivity
Fiducial
loaded or
tought?
A
’Select fiducial
menu
ESC
Program
transform 5
Fiducial
Video image
Teach command with different
grey-scale transformation
Output of uniqueness
No
Transform 1 Transform 2 Transform 3 Transform 4 Transform 5
ESC Return
(Repeat)
Program sensitivity
of transform 5
Standard values
(Accept standard
values)
Cancel
Option box
’Program sensitivity
of transform 5’
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.5 Teach Fiducial
Line engineer 5 - 47
5.5.3
Select
Fiducial
Menu
When the Teach fiducial option in the Main view menu is selected the following actions will be started:
The functions for the vision system are activated in the station computer
The Select fiducial menu will drop down.
The station computer asks the line computer for the list of fiducial numbers with commentaries and dis-
plays them on the screen. The transformation tables for the screen colors are held locally in the station
computer.
Fig. 5.5.2 Select fiducial menu
As the diagram shows, the menu offers the following options for selection.
Select gantry
Load fiducial
Define new fiducial
Change fiducial name
Save fiducial
Fiducial numbers list