80S-2080F480F4-680F5 User’s Manual - 第296页
SIPLACE 80S-2 0/F4/F4-6/F5 User’s Manual 5 Vision Functions Edition 03/98 from Software Vers ion SR.404.xx 5.6 Test Component Line engi neer 5 - 75 Menu Options ’Test Component’, Part 3 ’Measur. mode’ menu Measur . mod e…

SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 ”Vision Functions”
Edition 03/98 from Software Version SR.404.xx 5.6 ”Test Component”
Line engineer 5 - 74
Menu Options ’Test Component’, Part 2
Component
Input box
’Select contrast
sensitivity:
Program LUT
ESC
Accept data
Yes
Test component
GF
data loaded? A
’Select package form’
menu
No
OK: Accept / cancel setup
Pickup
Pickup
component from
feeder and rotate
it underneath the
comp. camera
DisplayMeasureTest
Video image
Display
synthetic
description
Video image
Measure
package form.
Display meas.
results.
Video image
Perform GF-
specific meas.
steps one after
the other
ESC ESC
Illumination
Package
dimension
Pin
dimension
Ball
illustration
Transform
Select comp. type
(80F only)
Measure mode
Video image
Manipulation
of
GF data
Video image
Manipulation
of
GF data
Video image
Manipulation
of
GF data
Video image
Manipulation
of
GF data
ESC ESC ESC
’Edit GF data’
menu options
Cancel Accept
Cubic
dull white
Cubic
dull black
Cubic
bright
Cylindrical
’Measure mode’
menu
’Select component
type’ option box
Cancel
ESC
See menu options
’Test component’ part 3, part 4
Store
image
Evaluation time
Video image
Evaluation time
ESC
Video image
is saved on
hard disk of
MC controller.

SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.6 Test Component
Line engineer 5 - 75
Menu Options ’Test Component’, Part 3
’Measur. mode’ menu
Measur. mode
Size
’Measur. mode’ menu
Cancel
Accept
Set
Row
Set
’Size
measur. mode’
menu
’Row
measur. mode’
menu
Corner
Set
’Corner
measur. mode’
menu
Lead
Set
’Lead
measur. mode’
menu
Grid
Set
’Grid
measur. mode’
menu
Ball Hex entries
Cancel Accept Cancel Accept Cancel Accept Cancel Accept Cancel Accept
Size
Row BallCorner Lead Grid
P1
P2
P2a
P3
P1
P1a
P1
P2
P3
P4
P5
P1
P1a
P2
P2a
P1
P2
P3
P3a
P1
P1a
P2
P3_5
Cancel Accept
’Measur. mode 2’ menu
’Size measur. mode’ menu
Resolution
of angle
calculation
low resolution
medium resol.
high resolution
very high resol.
Method for
calculation
of rotation
Automatic
selection
SWIN method
TWIN method
Integration
direction
In X-direction
in Y-direction
’Integration settings of Size meas. mode’ menu
Resolution in
measurement
direction
low resolution
medium resolution
high resolution
very high resolution
Resolution in
direction of
integration
low resolution
medium resolution
high resolution
very high resolution
Cancel Accept
Cancel Accept
Set
’Ball
measur. mode’
menu
Cancel Accept

SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.6 Test Component
Line engineer 5 - 76
Resolution in
meas. direction
low resolution
medium resol.
high resolution
very high resol.
Resolution in
direction of
integration
low resolution
medium resol.
high resolution
very high resol.
Menu Options ’Test Component’, Part 4
’Measur. mode’ menu
’Row measur. mode’ menu
Measurement
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Cancel Accept
Cancel Accept
Use package
form edges
For the
rotational
windows
For the
translational
windows
’Integration settings of Row
meas. mode’ menu
’Corner measur. mode’ menu
Measurement
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Cancel Accept
No. of pins to
be measured
at each corner
One window
across the whole
lead window
No. of pins at
each corner
Angle meas.
activated
yes / no
’Lead measur. mode’ menu
Measurement
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Cancel Accept
Window
Separately
for each pin
Combined
windows
’Grid measur. mode’ menu
Cancel Accept
Number of
balls to be
measured
’Ball measur. mode’ menu
Measurement
Fast
Robust
Cancel Accept
Evaluation
Position and
presence
Quality