80S-2080F480F4-680F5 User’s Manual - 第297页

SIPLACE 80S-2 0/F4/F4-6/F5 User’s Manual 5 Vision Functions Edition 03/98 from Software Vers ion SR.404.xx 5.6 Test Component Line engi neer 5 - 76 Resolu tion in meas. dire ction low re solut ion mediu m resol . high re…

100%1 / 744
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.6 Test Component
Line engineer 5 - 75
Menu Options ’Test Component’, Part 3
’Measur. mode’ menu
Measur. mode
Size
’Measur. mode’ menu
Cancel
Accept
Set
Row
Set
’Size
measur. mode’
menu
’Row
measur. mode’
menu
Corner
Set
’Corner
measur. mode’
menu
Lead
Set
’Lead
measur. mode’
menu
Grid
Set
’Grid
measur. mode’
menu
Ball Hex entries
Cancel Accept Cancel Accept Cancel Accept Cancel Accept Cancel Accept
Size
Row BallCorner Lead Grid
P1
P2
P2a
P3
P1
P1a
P1
P2
P3
P4
P5
P1
P1a
P2
P2a
P1
P2
P3
P3a
P1
P1a
P2
P3_5
Cancel Accept
’Measur. mode 2’ menu
’Size measur. mode’ menu
Resolution
of angle
calculation
low resolution
medium resol.
high resolution
very high resol.
Method for
calculation
of rotation
Automatic
selection
SWIN method
TWIN method
Integration
direction
In X-direction
in Y-direction
’Integration settings of Size meas. mode’ menu
Resolution in
measurement
direction
low resolution
medium resolution
high resolution
very high resolution
Resolution in
direction of
integration
low resolution
medium resolution
high resolution
very high resolution
Cancel Accept
Cancel Accept
Set
’Ball
measur. mode’
menu
Cancel Accept
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.6 Test Component
Line engineer 5 - 76
Resolution in
meas. direction
low resolution
medium resol.
high resolution
very high resol.
Resolution in
direction of
integration
low resolution
medium resol.
high resolution
very high resol.
Menu Options ’Test Component’, Part 4
’Measur. mode’ menu
’Row measur. mode’ menu
Measurement
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Cancel Accept
Cancel Accept
Use package
form edges
For the
rotational
windows
For the
translational
windows
’Integration settings of Row
meas. mode’ menu
’Corner measur. mode’ menu
Measurement
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Cancel Accept
No. of pins to
be measured
at each corner
One window
across the whole
lead window
No. of pins at
each corner
Angle meas.
activated
yes / no
’Lead measur. mode’ menu
Measurement
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Cancel Accept
Window
Separately
for each pin
Combined
windows
’Grid measur. mode’ menu
Cancel Accept
Number of
balls to be
measured
’Ball measur. mode’ menu
Measurement
Fast
Robust
Cancel Accept
Evaluation
Position and
presence
Quality
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.6 Test Component
Line engineer 5 - 77
5.6.3
Select Package Form
Menu
If you select the Test component option in the Main view menu this will launch the following actions:
The functions for the vision system are activated in the station computer
The Select package form menu will drop down.
The station computer will determine the package form numbers list with commentaries from the set-up.
Fig. 5.6.3 Select package form menu
The menu allows you to choose between the following options, as the diagram shows:
Selection of the camera types (80F
4
, 80F
4
-6 or 80F
5
machines only, see Section 5.10, Page 5 - 157).
Load GF data
Save GF data
NOTE
Buttons are active when the text on the button is black (rather than gray). This means that you can launch the
associated function by clicking on the button with the mouse.
The Load GF data button will, for example, only be active if you have previously clicked on a package form in
the lists field.
The Save GF data button will only be active if you have changed the package form parameters.