80S-2080F480F4-680F5 User’s Manual - 第334页
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functi on s Edition 03/98 from S oftware Version SR.404.xx 5.6 Test Component Line engi neer 5 - 113 Fig. 5.6.27 Measu ring mode option, Integration settings of Size measu…

5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
5.6 Test Component Edition 03/98 from Software Version SR.404.xx
5 - 112 Line engineer
– Medium resolution
Determining the angle every 4° within the angular tolerance
– High resolution
Determining the angle every 2° within the angular tolerance
– Very high resolution
Determining the angle every 1° within the angular tolerance
Method for calculating the rotation
Here you must specify the number of rotation windows in order to determine the angle:
– Automatic selection
The system selects the number of windows.
– SWIN method (Single Window)
Selects a single window. This method is suitable for small components and fluctuating dimensions.
– TWIN method (Two Windows)
Two windows are selected. This method is particularly suitable for rapid analysis, for PLCCs, for example.
However, this requires the structures to be investigated to lie in the center of the window. If this is not the
case, select just one window (SWIN method).
Integration settings
If you click on the ’Integration settings’ field, the Integration settings of Size measuring mode menu will
appear on screen.
Angular tolerance 0° - 15° 16° - 25° 26° - 45°
Determining the
angle for the
following
angles
- Angular tolerance
2
- 15° - 33°
0° - 8° - 18°
+Angular tolerance
2
0° - 8°
8° 0°
15° 8°
18°
33°
Tab. 5.6.2 Resolution for the angle calculation: Low resolution

SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.6 Test Component
Line engineer 5 - 113
Fig. 5.6.27 Measuring mode option, Integration settings of Size measuring mode menu
This menu is used to select the
– integration direction,
– the resolution in the measuring direction and
– the resolution in the integration direction.
Integration direction
In order to determine the angle, select the integration direction towards either the X or Y axis of the compo-
nent. We recommend that you select the longer edge.
Resolution in the measuring direction
Select this resolution in order to optimize the measuring times at the revolver head.
Resolution in the integration direction
Select this resolution in order to optimize the measuring times at the revolver head.
5.6.4.17 ’Row’ Measuring mode
Click on the ‘Setting’ field in the Row measuring mode menu to call up the following menu:

5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
5.6 Test Component Edition 03/98 from Software Version SR.404.xx
5 - 114 Line engineer
Fig. 5.6.28 Measuring mode option, Row measuring mode menu
This menu is used to
– specify the lead measuring method.
– use the package form edges for the rotation windows and/or translation windows.
Measurement
If the inner lead tips are mapped better that the outer tips, for example if a shiny lead is bent upwards slightly,
you can select one of the following options:
– measuring the tips via the inner tips of the leads, for bases, for example
– centre of the lead, centre measurement, for PLCC, SOJ, for example
– measuring the tips via the outer tips of the leads, for QFP, SOT, SO, for example
Use package form edges
–
for rotation windows
The package form edges can be used to optimally position the rotation windows. However, to do this, the
package form edge must be visible and it must not contain a row of leads.
–
for translation windows
The package form edges can be used to optimally position the translation windows. However, to do this,
the package form edge must be visible and it must not contain a row of leads.