SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functi on s Edition 03/98 from S oftware Version SR.404.xx 5.6 Test Component Line engi neer 5 - 115 Integration settings Once you have clic ked on the ‘Integrat ion setti…

100%1 / 744
5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
5.6 Test Component Edition 03/98 from Software Version SR.404.xx
5 - 114 Line engineer
Fig. 5.6.28 Measuring mode option, Row measuring mode menu
This menu is used to
specify the lead measuring method.
use the package form edges for the rotation windows and/or translation windows.
Measurement
If the inner lead tips are mapped better that the outer tips, for example if a shiny lead is bent upwards slightly,
you can select one of the following options:
measuring the tips via the inner tips of the leads, for bases, for example
centre of the lead, centre measurement, for PLCC, SOJ, for example
measuring the tips via the outer tips of the leads, for QFP, SOT, SO, for example
Use package form edges
for rotation windows
The package form edges can be used to optimally position the rotation windows. However, to do this, the
package form edge must be visible and it must not contain a row of leads.
for translation windows
The package form edges can be used to optimally position the translation windows. However, to do this,
the package form edge must be visible and it must not contain a row of leads.
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.6 Test Component
Line engineer 5 - 115
Integration settings
Once you have clicked on the ‘Integration settings’ field, the Row measuring mode integration settings
menu will appear on screen.
Fig. 5.6.29 Measuring mode option, Row measuring mode integration settings menu
Measuring times can be reduced by lowering the resolution in the measuring or integration direction. How-
ever, you must ensure that the structure to be analysed has a sufficient number of pixels. Otherwise, the mea-
suring quality will be compromised.
5.6.4.18 ‘Corner’ measuring mode
Click on the ‘Setting’ field in the ‘Corner’ measuring mode to call up the Corner measuring mode menu.
5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
5.6 Test Component Edition 03/98 from Software Version SR.404.xx
5 - 116 Line engineer
Fig. 5.6.30 Measuring mode option, Corner measuring mode menu
This menu is used to
specify the lead measuring method.
select the number of leads to be measured at each corner.
switch the angle measurement on or off.
Measurement
If the inner lead tips are mapped better that the outer tips, for example if a shiny lead is bent upwards slightly,
you can select one of the following options:
measuring the tips via the inner tips of the leads, for bases, for example
centre of the lead, center measurement, for PLCC, SOI, for example
measuring the tips via the outer tips of the leads, for QFP, SOT, SO, for example
Number of leads to be measured at each corner
If the lead no longer stands out well from the background, in the case of white plugs, for example, use this
option to specify the number of leads to be measured. However, to do this, the component must be fully
described in the line computer (FDC). In this case, there are no further lead measuring steps.
NOTE