SW 703 Option WPC - L oading Of Carrier : 105 Loading Of Carrier Loading the carrier in volves three steps: 1. Push in the refilled carrier 2. Turn t he latch inw ard to secure the carriers 3. Close the transparent acryl…

SW 703 Option WPC - Removal Of Carrier :
104
Removal Of Carrier
Removal of the carrier involves 3 steps:
1. Open the transparent acrylic door
2. Turn the latch outward to unlock the carriers
3. Pull out the empty carrier

SW 703 Option WPC - Loading Of Carrier :
105
Loading Of Carrier
Loading the carrier involves three steps:
1. Push in the refilled carrier
2. Turn the latch inward to secure the carriers
3. Close the transparent acrylic door

SW 703 Option WPC - Correct placement of Carrier in Unit :
106
Correct place ment of Carrier i n Unit
1. Carriers with correct placement will show a consistent
straight tape line running diagonally from top left to
right bottom
2. A distorted line indicates that some carriers are at the
wrong level
Note: Wrongly positioned carrier will result in wrong
component being picked up.