35,17&$55,$*(
Software Version 07SP02 User Manual 4.9
Drive Carriage to
Front Position
Selecting this diagnostic function moves the print carriage to the front start
position of the print stroke. Driving Carriage to Front Limit is displayed in
the prompt box.
Drive Carriage to
Paste Position
Selecting this diagnostic function moves the print carriage to a position that
clears the paste dispense unit if operated. Driving Carriage to Paste Posi-
tion is displayed in the prompt box.
Drive Carriage to
Rear Position
Selecting this diagnostic function moves the print carriage to the end of the print
stroke. Driving Carriage to Rear Limit is displayed in the prompt box.
Drive Carriage
Using Jog Buttons
Selecting this diagnostic function allows the user to position the print carriage
anywhere between the front and rear position using the two jog buttons. Use
Left Jog Button to move Print Carriage towards front and the Right Jog
Button to move it towards the rear is displayed in the prompt box.
Cycle Print
Carriage
Selecting this diagnostic function starts a continuous cycle of driving the print
carriage between its front and rear limits, pausing at each end for 2 seconds.
Print Cycling is displayed in the prompt box. The cycle is terminated if the
Stop key is used or the set cycle count is reached.
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count.
semi automatic
',$*1267,&6
352)/2:
4.10 User Manual Software Version 07SP02
PROFLOW
Selecting this diagnostics module opens the following window:
The menu bar changes to the following:
Next / Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight
bar.
Exit returns operation to the module diagnostics page.
Adjust opens the following window:
The menu bar changes to the following:
Next / Previous keys move the highlight bar up and down the list of diagnostic
parameters.
Incr. / Decr. keys change the value of the selected diagnostic parameter.
Exit returns operation to the ProFlow diagnostics page.
Home ProFlow Selecting this diagnostic function drives the ProFlow unit up to the home
position.
Drive System to
Contact Height
Selecting this diagnostic function drives the ProFlow unit onto the screen, (a
slight pressure seal, is made between the ProFlow transfer head and the
screen). There is no pressure applied to the paste cassette.
Drive System to
Print Height
Selecting this diagnostic function drives the ProFlow transfer head down to
printing pressure (as setup in the Edit Data board file). There is no pressure
applied to the paste cassette at this time.
ProFlow Diagnostics
11.42Kg
Home ProFlow
Drive System to Contact Height
Drive System to Print Height
Drive System Using Jog Buttons
Toggle Paste Pressure
Pressure Reading
ProFlow Fitted
Paste Cassette Low
ProFlow Pressure Regulator Fitted
ON
OFF
OFF
OFF
Run
Diagnost
Adjust Next Previous Exit
ProFlow Adjust Parameters
PFLOW CONTACT POS.
IDLE PRESSUE
0.0
0.2
mm
bar
Next Previous Incr. Decr. Exit
semi automatic
',$*1267,&6
352)/2:
Software Version 07SP02 User Manual 4.11
Drive System
Using Jog Buttons
Selecting this diagnostic function enables the ProFlow unit to be moved up or
down by means of the jog buttons.
Toggle Paste
Pressure
Selecting this diagnostic function initiates pressure onto the paste cassette.
Before initiating pressure to the paste cassette, the transfer head must be in
contact with, and have an adequate seal with the screen. A warning is displayed
if toggle paste pressure is selected with the transfer head off the screen.
Pressure Reading This diagnostic function continuously displays the current pressure in kg,
exerted from the squeegee pressure load cell onto the ProFlow unit.
ProFlow Fitted Indication of electrical connection of ProFlow to the machine software.
Paste Cassette
Low
ProFlow paste low sensor activated (on), indicating paste low or empty or,
deactivated (off).
ProFlow Pressure
Regulator Fitted
Switched to OFF indicates that the ProFlow unit is fitted with a mechanical
pressure regulator control. Switched to ON indicates that the software address-
able regulator control is activated, ie ProFlow not fitted with mechanical pres-
sure regulator.