182050 User manual - 第135页

semi automatic ',$*12 67, &6 648((*(( Software Version 07SP02 User Manual 4.13 Drive Rear Squeegee Using Jog Buttons Selectin g this diagnostic fu nction enables the rear squeegee to be driven up and down using …

100%1 / 266
semi automatic
',$*1267,&6
648((*((
4.12 User Manual Software Version 07SP02
SQUEEGEE Selecting this diagnostics module opens the following window:
The menu bar changes to the following:
Next / Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight
bar.
Exit returns operation to the module diagnostics page.
Home Front
Squeegee
Selecting this diagnostic function drives the front squeegee upwards to its home
position, as detected by its home sensor.
Home Rear
Squeegee
Selecting this diagnostic function drives the rear squeegee upwards to its home
position, as detected by its home sensor.
Front Squeegee to
Dwell Height
Selecting this diagnostic function drives the front squeegee to a position clear
of the top of the screen (default is 30mm).
Rear Squeegee to
Dwell Height
Selecting this diagnostic function drives the rear squeegee to a position clear of
the top of the screen (default is 30mm).
Rear Squeegee to
Flood Height
Selecting this diagnostic function drives the rear squeegee to the height set by
the flood reference height parameter.
Drive Front
Squeegee Using
Jog Buttons
Selecting this diagnostic function enables the front squeegee to be driven up
and down using the jog buttons. The right jog button drives the squeegee down
at slow speed and the left jog button drives it up, stopping immediately the
button is released. Use Left Jog Button to move the Squeegee upwards,
and the Right jog Button to move it downwards. is displayed in the message
prompt box.
Squeegee Diagnostics
Pressure Reading
NOT FITTED
Home Front Squeegee
Home Rear Squeegee
Front Squeegee To Dwell Height
Rear Squeegee To Dwell Height
Rear Squeegee To Flood Height
Drive Front Squeegee Using Jog Buttons
Drive Rear Squeegee Using Jog Buttons
Run
Diagnost
Next Previous Exit
semi automatic
',$*1267,&6
648((*((
Software Version 07SP02 User Manual 4.13
Drive Rear
Squeegee Using
Jog Buttons
Selecting this diagnostic function enables the rear squeegee to be driven up
and down using the jog buttons. The right jog button drives the squeegee down
at slow speed and the left jog button drives it up, stopping immediately the
button is released. Use Jog Button to move the Squeegee upwards, and
the Right jog Button to move it downwards. is displayed in the prompt box.
Pressure Reading This diagnostic function is not used on this machine.
semi automatic
',$*1267,&6
&$0(5$$;(6
4.14 User Manual Software Version 07SP02
CAMERA AXES
Selecting this diagnostics module opens the following window:
The menu bar changes to the following:
Next / Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight
bar.
Exit returns operation to the module diagnostics page.
Fiducial Setup enables screen fiducials to be located.
Adjust opens the following window:
The menu bar changes to the following:
Next / Previous keys move the highlight bar up and down the list of diagnostic
parameters.
Incr. / Decr. keys change the value of the selected diagnostic parameter.
Exit returns operation to the camera diagnostics page.
NOTE
These parameters are used in diagnostics only and have no affect on the
product board file.
OFF
OFF
Home Camera X Axis
Home Camera Y Axis
Camera Axis To Fiducial 1 Position
Camera Axis To Fiducial 2 Position
Drive to Board Stop Position
Restore Default Reference Position
Drive to Reference Position
Set Reference Position
Move Camera X Axis Using Jog Buttons
Move Camera Y Axis Using Jog Buttons
Initialise Vision System
Fiducial Lighting
Inspection Lighting
Cycle Camera System
Camera Diagnostics
.. more
Run
Diagnost
Adjust
Fiducial
Setup
Next Previous Exit
FIDUCIAL 1 X
FIDUCIAL 1 Y
FIDUCIAL 2 X
FIDUCIAL 2 Y
BOARD STOP X
BOARD STOP Y
CYCLE COUNT
Camera Cycle Test Parameters
243.0
241.1
7.3
8.8
125.0
165.0
50.0
mm
mm
mm
mm
mm
mm
Cycles