182050 User manual - 第151页
semi automatic 021,725 ,1752'8& 7,21 Software Version 07SP02 User Manual 5.1 CHAPTER 5 MONITOR INTRODUCTION The Monitor function al lows for t he settin g of the fol lowing f unctions: • Clear Batch • Batch Limi…

semi automatic
',$*1267,&6
5,6,1*7$%/(
4.28 User Manual Software Version 07SP02
Restore Default
Heights
Selecting this function restores the vision height to the default of 50mm and the
print height to the default of 127mm.
Set Reference
Vision Height
Selecting this function enables the rising table vision height to be set so that the
camera views the board fiducials in focus. This is achieved by driving the table
up or down while viewing the vision monitor until the fiducial is in focus.
Pressing Calibrate Vision Height changes the menu Bar showing the option
Confirm. Pressing Confirm sets the current height of the rising table, updating
the printer configuration file. Refer to the Technical Reference manual, Camera
and Vision System chapter for the camera reference position procedure.
Set Reference
Print Height
Selecting this function enables the print height to be set so that no gap exists
between the screen and board. Refer to the Technical Reference manual,
Rising Table chapter for the print height calibration procedure.
Drive Table Using
Jog Buttons
Selecting this function enables the right jog button to drive the rising table up at
slow speed and the left jog button to drive the table down, stopping immediately
the button is released.
Toggle Table Brake Selecting this function alternately switches the table brake on and off, while
continuously displaying the current status.
Toggle Vacuum
Tooling Valve
Selecting this function alternately switches the vacuum tooling solenoid on and
off, to supply and remove pneumatic pressure to the venturi vacuum pump,
continuously displaying the current status.
Cycle Rising Table Selecting this function first checks that the camera carriage is at the home
position, if not the rising table error message, ‘Table Movement Inhibited,
Camera Not Home’ is displayed. If the camera is in the home position, a
continuous cycle starts driving the rising table to print height, dwelling for two
seconds, driving the table down to its datum height, dwelling for two seconds
and repeating the cycle until Stop is pressed, or the Set Cycle Count has been
reached.
Rail Lifted Left This diagnostic function continuously displays the status of the rail lifted left
sensor. Off is displayed when the rail has been lifted.
Rail Lifted Right This diagnostic function continuously displays the status of the rail lifted right
sensor. Off is displayed when the rail has been lifted.
Table at Home This diagnostic function continuously displays the status of the home interlock
sensor. On is displayed when the rising table is in the home position.
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count.

semi automatic
021,725
,1752'8&7,21
Software Version 07SP02 User Manual 5.1
CHAPTER 5 MONITOR
INTRODUCTION The Monitor function allows for the setting of the following functions:
• Clear Batch
• Batch Limit
• System Disable
To access the monitor functions proceed as follows:
Select the Monitor button from the run menu.
The menu bar displays the following options:
Run
Open
Cover
Paste
Load
Clean
Screen
Setup Monitor Maint.
Clear
Batch
Batch
Limit
System
Disable
Exit

semi automatic
021,725
&/($5%$7&+
5.2 User Manual Software Version 07SP02
CLEAR BATCH Allows the user to reset cycle time, batch count, board count and throughput
information on the status page. To reset the batch proceed as follows:
1. Press Monitor (F7).
2. Press Clear Batch (F3).
3. Press Exit (F8).
Run
Open
Cover
Paste
Load
Clean
Screen
Setup Monitor Maint.
Clear
Batch
Batch
Limit
System
Disable
Exit
Clear
Batch
Batch
Limit
System
Disable
Exit