182050 User manual - 第16页
semi automatic 0$&+,1( 352*5$ 00,1* 67$*( (',7 $352' 8&7),/( 1.6 User Manual Software Version 0 7SP02 7. Use either the Incr . and Decr . keys (F6 - F7) o r the forward sl ash key (/) on the ke…

semi automatic
0$&+,1(352*5$00,1*
67$*((',7$352'8&7),/(
Software Version 07SP02 User Manual 1.5
STAGE 3 - EDIT A PRODUCT FILE
1. Select Edit Data (F3).
The following Edit Current Process Parameters window is displayed:
2. Select Incr. (F6). The message ‘Please type in the text, then press
Return’ is displayed. The menu softkeys are blanked out.
3. Type in the required product name and press Return using the keyboard.
4. Highlight Product ID using the Next key (F4). Select Incr. (F6). The
message ‘Please type in the text, then press Return’ is displayed. The
menu softkeys are blanked out.
5. Type in the required product ID and press Return using the keyboard.
NOTE
If 2D Inspection is enabled and the product file being copied has an
assigned inspection file, the user is prompted to make a copy of the file.
(See 2Di Setup in 2Di Inspection chapter later in this manual).
6. Use the Next and Previous keys (F4 - F5) to highlight the relevant param-
eter.
Mode
Load
Data
Edit
Data
Setup
Squeegee
Change
Screen
Change
Tooling
Change
Language
Exit
PRODUCT NAME
PRODUCT ID
SCREEN ADAPTOR
SCREEN IMAGE
CUSTOM SCREEN
BOARD WIDTH
BOARD LENGTH
BOARD THICKNESS
FRONT PRINT SPEED
REAR PRINT SPEED
FLOOD SPEED
PRINT FRONT LIMIT
PRINT REAR LIMIT
FRONT PRINT PRESSURE
DEFAULT
Alignment Test Board
NONE
EDGE
DISABLED
250.0
250.0
1.6
150
150
20
0.0
0.0
5.0
mm
mm
mm
mm/s
mm/s
mm/s
mm
mm
kg
.. more
Edit Current Process Parameters
Save Next Previous Incr. Decr. Exit
Save Next Previous Incr. Decr. Exit
Save Next Previous Incr. Decr. Exit

semi automatic
0$&+,1(352*5$00,1*
67$*((',7$352'8&7),/(
1.6 User Manual Software Version 07SP02
7. Use either the Incr. and Decr. keys (F6 - F7) or the forward slash key (/) on
the keyboard to change the parameter value.
NOTE
A definition of all editable parameters is contained at the end of this chapter.
8. Select Save (F2). The message ‘Saving fiducial data - Please wait Board
data file saved’ is displayed.
9. Repeat Steps 6 - 8 for the remaining parameters.
10. Select Exit (F8).
Save Next Previous Incr. Decr. Exit
Save Next Previous Incr. Decr. Exit
Save Next Previous Incr. Decr. Exit

semi automatic
0$&+,1(352*5$00,1*
67$*($),7648((*((6
Software Version 07SP02 User Manual 1.7
STAGE 4A - FIT SQUEEGEES
If ProFlow was used when running the last product, carry out the ProFlow to
Squeegee Replacement Procedure, (Squeegee Module chapter - Replacement
Procedures of Technical Reference manual refers).
1. Select Setup (F6).
2. Select Setup Squeegee (F4).
3. Select Change Squeegee (F1).
4. Raise the printhead cover.
5. Before fitting the squeegees to the machine, fix the paste deflectors to each
end of the squeegee assemblies, using the screws supplied. Ensure that
the bottom edge of the deflector is above the lower edge of the squeegee
blade. The setting of the paste deflectors is carried out later in this chapter.
NOTE
The deflectors are handed so care must be taken to fix the correct deflector
to each end of the squeegee assemblies.
Run
Open
Cover
Paste
Load
Clean
Screen
Setup Monitor Maint.
Mode
Load
Data
Edit
Data
Setup
Squeegee
Change
Screen
Change
Tooling
Change
Language
Exit
Change
Squeegee
Calibrat
Heights
Exit