182050 User manual - 第206页
semi automatic ',163(&7,21 0(183$5$ 0(7(5 6 7.32 User Manual Software Ve rsion 07SP02 Paste W arning This parameter sets the amount of p aste on pad requ ired to initiate a warni ng. Paste Alarm This paramete…

semi automatic
',163(&7,21
0(183$5$0(7(56
Software Version 07SP02 User Manual 7.31
NOTE
If the machine inspection page is set to GUI 2Di, all displayed sites are colour
coded, depending on their priority setting, (following table refers):
Limit Set ID The unique name given to a set of limits which can be applied to any site. This
enables different sites to be inspected according to different limits. The name
can have a maximum of 20 characters. A maximum of 14 limit sets can be
created.
Paste Scaling This parameter enables adjustment of the paste scaling value for the current
site, to cause the value of paste present on the pad, currently selected in the
inspection list, to be reported as 100%. This parameter is used in conjunction
with the Auto Scale function.
Site X Coord The coordinate of a site taken from the front left corner of the board, in the X
direction.
Site Y Coord The coordinate of a site taken from the front left corner of the board, in the Y
direction.
Site Width The width of the site to be inspected.
Site Height The height of the site to be inspected.
Site Priority Display Colour
Every Cycle
Green
General
Yellow
Not Inspected
Blue
Minimum Maximum Increments
0.01 2.00 0.01
Minimum Maximum Increments
0.0mm Board Length 0.1mm
Minimum Maximum Increments
0.0mm Board Width 0.1mm
Minimum Maximum Increments
0.5mm 4.0mm 0.01mm
Minimum Maximum Increments
0.5mm 6.5mm 0.01mm

semi automatic
',163(&7,21
0(183$5$0(7(56
7.32 User Manual Software Version 07SP02
Paste Warning This parameter sets the amount of paste on pad required to initiate a warning.
Paste Alarm This parameter sets the amount of paste on pad required to initiate an alarm.
Board Graphic X The position of the inspection window on the board side. This parameter is used
to finely adjust the inspection window in the X direction.
Board Graphic Y The position of the inspection window on the board side. This parameter is used
to finely adjust the inspection window in the Y direction.
Window Left This parameter sets the position of the histogram window relative to the centre
of the image.
The Minimum and Maximum values are calculated from the vision calibration
and vary from machine to machine. Increments - 0.1mm.
Window Top This parameter sets the position of the histogram window relative to the centre
of the image.
The Minimum and Maximum values are calculated from the vision calibration
and vary from machine to machine. Increments - 0.1mm.
Window Width This parameter sets the width of the histogram window.
The Minimum and Maximum values are calculated from the vision calibration
and vary from machine to machine. Increments - 0.1mm.
Window Height This parameter sets the height of the histogram window.
The Minimum and Maximum values are calculated from the vision calibration
and vary from machine to machine. Increments - 0.1mm.
Screen Vertical This parameter sets the level of stencil vertical light.
Minimum Maximum Increments
0% 100% 1%
Minimum Maximum Increments
0% 100% 1%
Minimum Maximum Increments
-3.5mm 3.5mm 0.01mm
Minimum Maximum Increments
-3.5mm 3.5mm 0.01mm
Minimum Maximum Increments
0151

semi automatic
',163(&7,21
0(183$5$0(7(56
Software Version 07SP02 User Manual 7.33
Board Vertical This parameter sets the level of board vertical light.
Limit Set Options This parameter enables/disables the paste alarm action.
Minimum Maximum Increments
0151