182050 User manual - 第22页

semi automatic 0$&+,1( 352*5$ 00,1* 67$*($ ),7 648((* ((6 1.12 User Manual Software Ve rsion 07SP02 13. Press Exit (F8) . 14. Press Save (F3). Or: 15. Using S tep Up and Step Down (F6 and F7) as necessary to r…

100%1 / 266
semi automatic
0$&+,1(352*5$00,1*
67$*($),7648((*((6
Software Version 07SP02 User Manual 1.11
6. Remove the stencil from the machine.
7. Lower the printhead cover.
8. Press the System button.
9. Press Calibrat Heights (F2).
The message Ensure that the Correct Squeegees are fitted is dis-
played.
10. Press Continue (F1).
The message Set Squeegee Pressure Height is displayed.
Either:
11. Press Adjust (F2).
The following window is displayed:
12. Using Next, Previous, Incr. and Decr. (F4, F5, F6 and F7) enter the
squeegee heights parameters as necessary.
Change
Squeegee
Calibrat
Heights
Exit
Continue
Restore
Defaults
Exit
Adjust Save
Front
Squeegee
Rear
Squeegee
Step
Up
Step
Down
Exit
Squeegee Heights Parameters
Front Zero Ref
Rear Zero Ref
4000
4040
Next Previous Incr. Decr. Exit
semi automatic
0$&+,1(352*5$00,1*
67$*($),7648((*((6
1.12 User Manual Software Version 07SP02
13. Press Exit (F8).
14. Press Save (F3).
Or:
15. Using Step Up and Step Down (F6 and F7) as necessary to raise or lower
the front squeegee until it just touches the front rail.
16. Press Rear Squeegee (F5).
17. Using Step Up and Step Down (F6 and F7) as necessary to raise or lower
the rear squeegee until it just touches the front rail.
18. Press Save (F3).
19. Press Exit (F8).
20. Press Exit (F8).
21. Press Exit (F8).
Next Previous Incr. Decr. Exit
Adjust Save
Front
Squeegee
Rear
Squeegee
Step
Up
Step
Down
Exit
Adjust Save
Front
Squeegee
Rear
Squeegee
Step
Up
Step
Down
Exit
Adjust Save
Front
Squeegee
Rear
Squeegee
Step
Up
Step
Down
Exit
Adjust Save
Front
Squeegee
Rear
Squeegee
Step
Up
Step
Down
Exit
Adjust Save
Front
Squeegee
Rear
Squeegee
Step
Up
Step
Down
Exit
Adjust Save
Front
Squeegee
Rear
Squeegee
Step
Up
Step
Down
Exit
Change
Squeegee
Calibrat
Heights
Exit
Mode
Load
Data
Edit
Data
Setup
Squeegee
Change
Screen
Change
Tooling
Change
Language
Exit
semi automatic
0$&+,1(352*5$00,1*
67$*(%352)/2:6(783
Software Version 07SP02 User Manual 1.13
STAGE 4B - PROFLOW SETUP
If squeegees were used when running the last product, carry out the Squeegees
to ProFlow Replacement Procedure, see Technical Reference manual, ProFlow
Module chapter - Replacement Procedures.
For setting the contact position, carry out the ProFlow Contact Position Setup,
see Technical Reference manual, ProFlow Module chapter - Adjustments and
Settings.