NOTE
Prior to completion, slowly retract the nozzle from the filling hole to avoid
creation of air bubbles within the paste fill.
5. Move the recharging unit to the centre filling port, and repeat Step 4.
6. Move the recharging unit to the last filling port and repeat Step 4 until the
void is full.
7. Knead the transfer head diaphragm so that the paste is dispersed evenly
along it’s length. The top of the diaphragm must be flat (not ballooned
upwards). Figures below refers.

semi automatic
&21680$%/(5(3/(1,6+0(176
352)/2:
Software Version 07SP02 User Manual 8.53
8. Fit the transfer head unit to the maintenance stand and remove the base
cover.
9. Using the recharging unit with long nozzle, fill the length of each side of the
unit, behind the wiper units, (figure below refers).
10. Apply the paste along the length of the centre, between the wipers, filling
paste level with the wiper blade edges, (figure below refers).

semi automatic
&21680$%/(5(3/(1,6+0(176
352)/2:
8.54 User Manual Software Version 07SP02
11. Using a spatula, smooth and level the paste to the height of the blades.
NOTE
Pack any excess paste on the spatula between the blades.
12. If necessary clean the wiper blades and skis so that they are not contami-
nated with paste.
NOTE
For effective cleaning, DEK recommend the use of IPA impregnated wipes
(Part No.141150).
13. Fit cover to the unit.
14. Fit the transfer head unit to the ProFlow pressure mechanism on the
machine, (refer to ProFlow chapter in the Technical Reference manual for
detailed information on unit removal/fitting).
Replenishment 1. If the ProFlow unit is in the home position continue with Step 2. If the
ProFlow unit is in the contact position go to Step 19.
2. Select Setup (F6).
3. Select Setup ProFlow (F4).
4. Select Load Cassette (F4). The message ‘Has the ProFlow unit’s base
cover been removed?’ is displayed.
5. If the ProFlow unit’s base cover is still fitted continue with Step 6. If the
ProFlow unit’s base cover has been removed go to Step 12.
=
Run
Open
Cover
Paste
Load
Clean
Screen
Setup Monitor Maint.
Mode
Load
Data
Edit
Data
Setup
ProFlow
Change
Screen
Change
Tooling
Change
Language
Exit
Change
ProFlow
Load
Cassette
Exit