182050 User manual - 第82页
semi automatic 0$&+,1( 352*5$ 00,1* 0(183$5$ 0(7(5 6 1.72 User Manual Software Ve rsion 07SP02 MENU P ARAMETERS Each product has a set of parameters whic h are unique to that p articula r product and which need to …

semi automatic
0$&+,1(352*5$00,1*
67$*(35,17,158102'(
Software Version 07SP02 User Manual 1.71
10. Repeat Steps 8 and 9 for the other deflector.
11. Lower the printhead cover.
12. Press the System button.
13. Select Continue (F1).
14. After the squeegee has moved approximately 20mm, select Stop Cycle
(F2).
15. Raise the printhead cover.
16. Check the deflectors are not touching the stencil.
17. Lower the printhead cover.
18. Press the System button.
19. Select Continue (F1).
20. Repeat Steps 6-19 for the other squeegee.
21. The printer operates continuously. The menu bar displays the following
options, these may be selected at any time during a print run:
End Run Selecting this option stops the printer on completion of the current print cycle.
Stop Cycle Selecting this option stops the printer immediately, halting all actions.
Continue
End
Run
Stop
Cycle
Continue
End
Run
Stop
Cycle

semi automatic
0$&+,1(352*5$00,1*
0(183$5$0(7(56
1.72 User Manual Software Version 07SP02
MENU PARAMETERS
Each product has a set of parameters which are unique to that particular product
and which need to be setup to obtain acceptable printing results. These
parameters are listed below with a definition of each as an aid to machine setup.
Product Name The file name for the particular product. The name can consist of up to eight
alphanumeric characters with no punctuation.
Product ID The product ID is a parameter that allows a description of the product. This
string may be up to 32 characters long, but only the first 20 characters are
displayed.
Image Detail This parameter allows the user to modify the stencil image data of the selected
screen library file. Once selected, pressing Incr. or Decr. Keys opens the Image
Detail Configuration page.
NOTE
This parameter is only displayed, if Screen Size in Set Preferences has been
selected to Screen Library.
Mesh Front This parameter sets the distance between the inner edge of the stencil frame
and the stencil glue line at the front of the frame. It defines the area that should
not be contacted by the squeegees/ProFlow.
Mesh Rear This parameter sets the distance between the inner edge of the stencil frame
and the stencil glue line at the rear of the frame. It defines the area that should
not be contacted by the squeegees/ProFlow.
Mesh Left This parameter sets the distance between the inner edge of the stencil frame
and the stencil glue line at the left of the frame. It defines the area that should
not be contacted by the squeegees/ProFlow.
Mesh Right This parameter sets the distance between the inner edge of the stencil frame
and the stencil glue line at the right of the frame. It defines the area that should
not be contacted by the squeegees/ProFlow.
Minimum Maximum Increment Default
0.0mm Screen Length - 250.0mm 0.1mm 38.0mm
Minimum Maximum Increment Default
0.0mm Screen Length - 250.0mm 0.1mm 38.0mm
Minimum Maximum Increment Default
0.0mm Screen Width - 250.0mm 0.1mm 38.0mm
Minimum Maximum Increment Default
0.0mm Screen Width - 250.0mm 0.1mm 38.0mm

semi automatic
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 07SP02 User Manual 1.73
Image X This parameter defines the dimension in the X axis from the right inner edge of
the stencil frame to either:
Right hand edge of the image - right justified image
Left hand edge of the image - left justified image
Centre line of the image - centre justified image
Image Y This parameter defines the dimension in the Y axis from the front inner edge of
the stencil frame to either:
Front edge of the image - front justified image
Rear edge of the image - rear justified image
Centre line of the image - centre justified image
Image X
Justification
This parameter defines the position of the image about the Image X parameter.
The image can be left, right or centre justified about Image X. Options are:
Image Y
Justification
This parameter defines the position of the image about the Image Y parameter.
The image can be front, rear or centre justified about Image Y. Options are:
Minimum Maximum Increment Default
60.0mm Screen Length - 100.0mm 0.1mm 330.4mm
Minimum Maximum Increment Default
60.0mm Screen Width - 100.0mm 0.1mm 330.4mm
Option Default
Left Centre
Right
Centre
Option Default
Front Centre
Rear
Centre