semi automatic 0$&+,1( 352*5$ 00,1* 0(183$5$ 0(7(5 6 1.82 User Manual Software Ve rsion 07SP02 V ortex Solvent Rate (V ortex USC) This p arameter set s the f requency (in cl eaning cycles) a t which solv ent is dis…

semi automatic
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 07SP02 User Manual 1.81
Front Paste
Recovery
This parameter sets the extent of paste roll recovery movement while beginning
the rearward print stroke. The movement is measured forward from the print
stroke start position.
Rear Paste
Recovery
This parameter sets the extent of paste roll recovery movement while beginning
the forward print stroke. The movement is measured rearward from the print
stroke start position.
Screen Clean
Mode 1 (including
Vacuum)
This parameter sets the mode of operation of the screen cleaner for the first
clean mode. When selected this parameter opens a window that allows a
screen clean option sequence to be chosen. The sequence includes six stages,
each of which may be one of the following cleaning operations:
Screen Clean
Rate 1
This parameter sets the number of print cycles between the cycling of the
screen cleaner for the first screen clean rate.
Vortex Cassette
Life (Vortex USC)
This parameter sets the number of cleaning strokes that are applied before a
cleaning cassette is replaced.
Vortex Clean Rate
(Vortex USC)
This parameter sets the frequency (in print cycles) at which screen cleaning
occurs.
Minimum Maximum Increment Default
0.0mm 15.0mm
(Subject to front turn-
around envelope)
1.0mm 5.0mm
Minimum Maximum Increment Default
0.0mm 15.0mm
(Subject to rear turn-
around envelope)
1.0mm 5.0mm
Cleaning Operation Note
Wet A warning is given if the end stroke is wet.
Dry
Vac
None
Minimum Maximum Increment
0 (Screen cleaner off) 200 1
Minimum Maximum Increment Default
0.0 200.0 1.0 20.0
Minimum Maximum Increment Default
0.0 200.0 1.0 0.0

semi automatic
0$&+,1(352*5$00,1*
0(183$5$0(7(56
1.82 User Manual Software Version 07SP02
Vortex Solvent
Rate (Vortex USC)
This parameter sets the frequency (in cleaning cycles) at which solvent is
dispensed.
Vortex Vacuum
Start (Vortex USC)
The distance, in from the front edge of the board, where vacuum is applied.
Vortex Vacuum
Stop (Vortex USC)
The distance, in from the front edge of the board, where vacuum application is
stopped.
Vortex Vacuum
Rate (Vortex USC)
This parameter sets the frequency (in cleaning cycles) at which vacuum is
applied.
Vortex Vacuum
Period (Vortex
USC)
This parameter sets the period for which vacuum is applied.
Vacuum Clean
Start Time
This parameter sets the time in seconds the vacuum is applied for before the
screen clean stroke begins.
NOTE
This parameter is only displayed with a Blue USC fitted and the Under Screen
Cleaner parameter in Set Preferences set to Vacuum.
Minimum Maximum Increment Default
1.0 10.0 1.0 1.0
Minimum Maximum Increment Default
Vacuum Stop Board Width 1.0 0.0
Minimum Maximum Increment Default
-100.0mm Vacuum Stop 1.0mm 0.0mm
Minimum Maximum Increment Default
1.0 10.0 1.0 1.0
Minimum Maximum Increment Default
1.0 sec 10.0 secs 1.0 sec 5.0 secs
Minimum Maximum Increment Default
0.0 sec 5.0 secs 0.5 sec 1.0 secs

semi automatic
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 07SP02 User Manual 1.83
Clean After The Automatic screen clean after downtime process chosen in the above menu
parameter is carried out after a countdown of the number of minutes set in this
parameter.
Dry Clean Speed This parameter sets the speed of the screen clean dry wipe for optimization.
Wet Clean Speed This parameter sets the speed of the screen clean wet wipe for optimization.
Vac Clean Speed This parameter sets the speed of the screen clean vacuum for optimization.
Front Start Offset
(Blue USC)
This parameter determines the distance from the front edge of the board that
the cleaning stroke must start.
Front Start Offset
(Vortex USC)
This parameter determines the distance from the front edge of the board that
the cleaning stroke must finish.
Rear Start Offset
(Blue USC)
This parameter determines the distance from the rear edge of the board that
cleaning must complete.
Rear Start Offset
(Vortex USC)
This parameter determines the distance from the rear edge of the board that
cleaning must start.
Minimum Maximum Increment
5.0 mins 120.0 mins 1.0 min
Minimum Maximum Increment
10.0mm/sec 120.0mm/sec 1.0mm/sec steps
Minimum Maximum Increment
10.0mm/sec 100.0mm/sec 1.0mm/sec steps
Minimum Maximum Increment
10.0mm/sec 100.0mm/sec 1.0mm/sec steps
Minimum Maximum Increment
0.0mm 60.0mm 1.0mm
Minimum Maximum Increment Default
-60.0mm 60.0mm 1.0mm 30.0mm
Minimum Maximum Increment
0.0mm 60.0mm 1.0mm
Minimum Maximum Increment Default