YSM20R_YSM20WR_Mainte_E - 第102页

3-41 3 Periodic maintenance items 6 Clean the inside of spline shaft. 1. Insert the nozzle of the cleaning kit into the cleaning hole of the spline shaft. 2. Pour ethanol into the spline shaft air path to clean away dust…

100%1 / 207
3-40
3
Periodic maintenance items
5. 1-year maintenance
This section describes 1-year maintenance items.
5.1 Cleaning spline shaft
As a general guide, the spline shaft should be cleaned once a year. Following procedure below to clean the
spline shaft.
5.1.1 HM head
1
Return all nozzles to nozzle
station.
1. Open the [Unit] - [Head] screen.
2. Select desired head unit from "Table
Select".
3. Press the [Nozzle Change] button.
4. Select "ALL" for "Head Number" and
select "Store Nozzle" for "Nozzle Type" on
the "Nozzle Change" screen.
5. Press the [OK] button to return all nozzles
to the nozzle station.
n
NOTE
If the machine is not equipped with a nozzle station,
press the emergency stop button and then remove the
nozzles manually.
e
2
Move the head unit.
1. Press the emergency stop button and
then open the machine safety cover.
2. If the machine is carriage type, detach
carriage to easily access to the head unit.
3. Move the head unit to a convenient
position for maintenance work.
3
Remove the maintenance bolt and
air hose.
Use a flat-head screwdriver or precision
wrench to remove the maintenance bolt
and pull out the air hose.
4
Mount the Z-axis at the work position.
As shown in the figure on the right, move the
shaft to a position where the Z-axis linear
scale is hidden and insert the hex wrench into
the Z-axis mounting hole to mount the Z-axis.
n
NOTE
A hex wrench may not be inserted easily as cables are
around the head. In this case, use a wire (less than
φ
2.5
mm), etc. to mount the Z-axis.
5
Make the preparations for cleaning.
1. Place a paper cup or cloth under the
head to be cleaned.
2. Fill the cleaning kit with ethanol.
Removing maintenance bolt and air hose
Step 3
Maintenance bolt
Air hose
53354-KMK-00
Mounting the Z-axis
Step 4
Hex wrench
φ2.5 mm
Z-axis
mounting hole
53355-KMK-00
3-41
3
Periodic maintenance items
6
Clean the inside of spline shaft.
1. Insert the nozzle of the cleaning kit into
the cleaning hole of the spline shaft.
2. Pour ethanol into the spline shaft air path
to clean away dust and grime.
c
CAUTION
Be sure to insert the cleaning kit tip 25 mm or more. If
the cleaning kit tip is inserted insufficiently, ethanol may
flow into the packing.
7
Blow air into the spline air path.
1. Prepare the air blow tool (option) and
connect it to the air connector on the
left or right of the machine.
2. Cover the portion where the air hose has
been disconnected so that no air leaks.
Then blow the air into the inside of the
spline shaft.
3. Check that contaminant is no longer
discharged from the spline shaft tip.
n
NOTE
Repeat Step 6 and Step 7 until ethanol that flows out
from the spline shaft becomes clean.
8
Return the head to its original state.
1.
Install the maintenance bolt and return the
air hose and nozzle to their original states.
2.
Pull out the hex wrench ( or wire etc.) that
mounts the Z-axis.
n
NOTE
If removed nozzles manually from the head, return
them to the original position of the head.
25 mm
or more
Cleaning the spline
Step 6
Ethanol
Cleaning kit
53356-KMK-00
Blowing the air path
Step 7
Push this portion
with finger.
Air blow tool
53357-KMK-00
3-42
3
Periodic maintenance items
5.1.2 FM head
1
Return all nozzles to nozzle
station.
1. Open the [Unit] - [Head] screen.
2. Select desired head unit from "Table
Select".
3. Press the [Nozzle Change] button.
4. Select "ALL" for "Head Number" and
select "Store Nozzle" for "Nozzle Type" on
the "Nozzle Change" screen.
5. Press the [OK] button to return all nozzles
to the nozzle station.
n
NOTE
If the machine is not equipped with a nozzle station,
press the emergency stop button and then remove the
nozzles manually.
e
2
Move the head unit.
1. Press the emergency stop button and
then open the machine safety cover.
2. If the machine is carriage type, detach
carriage to easily access to the head unit.
3. Move the head unit to a convenient
position for maintenance work and
remove all nozzles.
3
Disconnect the air hose and remove
the cover.
1. Remove screws on front cover with hex
wrench (3) holding the cover to avoid
falling.
2. Disconnect the air hose from the top and
bottom joints.
n
NOTE
Disconnect air hose attaching to the front cover.
4
Remove the maintenance bolt and
joint.
Use a flat-head screwdriver or wrench to
remove the maintenance bolt and joint.
5
Make the preparations for cleaning.
1. Place a paper cup or cloth under the
head to be cleaned.
2. Fill the cleaning kit with ethanol.
6
Clean the inside of spline shaft.
1. Insert the nozzle of the cleaning kit into
the cleaning hole of the spline shaft.
2. Pour ethanol into the spline shaft air path
to clean away dust and grime
c
CAUTION
Be sure to insert the nozzle tip 25 mm or more. If the
nozzle tip is inserted insufficiently, ethanol may flow into
the packing, etc.
Removing the front cover
Step 3
Rear side of front cover
Front cover
Front cover
Tube holder
Cover clamp bolt
Joint
Air hose
53358-KMK-00
Removing maintenance bolt and joint
Step 4
Maintenance bolt
wrench
Joint
53359-KMK-00
Cleaning the spline
Step 6
Ethanol
Cleaning kit
25 mm
or more
53360-KMK-00