4
Maintenance of options
1. Ionizer
As the ionizer is used for a long time, the discharge needle (electrode) is worn out and deteriorates.
Additionally, the periodic cleaning work is needed to maintain the static elimination effect.
n
LED display on ionizer main unit
Ionizer
Indicator panel
Ionizer indicator panel
POWER ALARMRUN
CLEANING
RESET
CLEANING TIMER
T SELECT
53400-KMK-00
n
Ionizer indication
POWER The green LED lights up when the electric power is supplied normally.
RUN The green LED stays on during the normal operation.
ALARM
The red LED lights up if the discharge needle has deteriorated or an inner unit/
device is experiencing an error. The machine main body also generates an
alarm.
CLEANING TIMER
When the duration of time set up by operating the trimmer of T.SELECT has
expired, the “CLEANING” yellow LED lights up. Pressing the “RESET” button
makes the yellow LED go out. * Note that this timer is not set up at the time of
shipping from the factory.
n
NOTE
The performance and capability of the ionizer to remove static electricity depends on the operating environment or
the materials and shape of the items that the static electricity is removed. YAMAHA does not guarantee such
performance or capability.
c
CAUTION
The tip of the ionizer discharge needle is sharp and the voltage is applied. The power supply to the ionizer is stopped
by opening the safety cover. However, make sure not to touch the tip of the ionizer discharge needle when
performing maintenance in the machine.
4-2
4
Maintenance of options
1.1 Cleaning the ionizer discharge needle (Monthly)
Perform this work monthly or if the LED on the ionizer main unit is lit red.
1
Power off the ionizer.
1.
Press the emergency stop button and
then open the machine safety cover to
stop the power supply to the ionizer.
2.
Check that the green LED of the "POWER"
on the ionizer is turned off.
w
WARNING
A VOLTAGE REMAINS ON THE DISCHARGE NEEDLE
IMMEDIATELY AFTER TURNING OFF THE POWER. BE AWARE
THAT TOUCHING THE DISCHARGE NEEDLE IMMEDIATELY
AFTER TURNING OFF THE POWER IS HAZARDOUS.
2
Turn off the air supply.
Turn the air supply/exhaust switch (valve) on
the lower left of the machine clockwise (EXT)
to turn off the main air.
3
Clean the discharge needle.
1. Apply absolute ethanol to a cotton swab
slightly and clean the discharge needle.
2. Leave the cleaned discharge needle for
a while until it dries.
n
NOTE
It is also possible to clean the discharge needle by
detaching the discharge needle unit. See "1.2
Replacing the ionizer discharge needle (2-year)" on
next page for attaching and detaching the discharge
needle unit.
c
CAUTION
Do not dip the discharge needle unit to the absolute
ethanol when cleaning the detached discharge needle
unit. If applying a high voltage while absolute ethanol
remains in the unit, the ionizer main unit may be
damaged.
4
Supply the air and power on the
ionizer.
1. Turn the air supply/exhaust switch and
supply the air to the machine.
2. Close the machine safety cover and
press the [READY] button.
3.
Check that the green LED of the "POWER"
on the ionizer is turned on. Make sure that
no error is occurring.
Step 3
Cotton swab with
absolute ethanol
Cleaning the discharge needle
Discharge needle
53401-KMK-00
4-3
4
Maintenance of options
1.2 Replacing the ionizer discharge needle (2-year)
Replace ionizer discharge needle (KJX-M83P1-00X : NEEDLE SPARE SET/5 pcs) once every 2 years or if an error
still occurs even after performed "1.1 Cleaning the ionizer discharge needle (Monthly)". An Ionizer uses 10
discharge needles. As one each of ionizers are attached on front and rear of the machine if it is the front and rear
fixed bank type, 4 discharge needle units are required when performing maintenance work of machine.
1
Power off the ionizer.
1.
Press the emergency stop button and
then open the machine safety cover to
stop the power supply to the ionizer.
2.
Check that green LED of "POWER" on
ionizer is turned off.
w
WARNING
A VOLTAGE REMAINS ON THE DISCHARGE NEEDLE
IMMEDIATELY AFTER TURNING OFF POWER. BE AWARE
THAT TOUCHING DISCHARGE NEEDLE IMMEDIATELY AFTER
TURNING OFF POWER IS HAZARDOUS.
2
Turn off the air supply.
Turn the air supply/exhaust switch (valve) on
the lower left of the machine clockwise (EXT)
to turn off the main air.
3
Detach the discharge needle unit.
1.
Insert the detaching tool, an ionizer
accessory, aligning the discharge needle
unit grooves.
2. Rotate the detaching tool
counterclockwise 1/8 of a turn.
3.
Detach the discharge needle unit.
4
Reattach the discharge needle unit.
1. Insert the discharge needle unit aligning
with the grooves of the ionizer.
2.
Insert the detaching tool aligning the
discharge needle unit grooves.
3. Rotate the detaching tool clockwise 1/8
of a turn.
c
CAUTION
The O-ring is in between the discharge needle unit and
ionizer. Make sure not to drop it.
5
Supply air and power on ionizer.
1. Turn the air supply/exhaust switch (valve)
and supply the air to the machine.
2. Close the machine safety cover and
press the [READY] button.
3.
Check that the green LED of the "POWER"
on the ionizer is turned on. Make sure that
no error is occurring.
n
NOTE
If continuing to receive error even after replacing
discharge needle unit, contact YAMAHA sales
representatives.
See the manufacturer's instructions for detailed
specifications of the ionizer.
Step 3
Aligning with grooves.
Make sure not to drop O-ring.
Detaching tool
Discharge needle unit
Removing the discharge needle unit
53402-KMK-00
Replacing the discharge needle unit
Step 4
Align with grooves.
Detaching tool
New discharge needle unit
Make sure not to drop O-ring.
Insertion port
53403-KMK-00