Maintenance of options
3. Nozzle station
3.1 Checking and cleaning nozzle sensor (1 year)
When the machine is equipped with the nozzle station (option), it is necessary to periodically check the nozzle
detection sensor status.
c
CAUTION
If the nozzle station sensor cannot detect the nozzle correctly, the nozzle change does not operate correctly or the
production cannot continue due to nozzle detection error.
e
1
Make the preparations for work.
1. Return all nozzles to the nozzle station.
2. Press the emergency stop button and
then open the machine safety cover.
2
Open the shutter of the nozzle
station (hereafter "ANC").
1. Open the [Unit] - [Head] screen.
2. Press the [Nozzle. Stn Shutter] button to
open the ANC shutter.
3
Open the Utilities mode.
1. Press the [Utilities] button on the left of
the screen.
2. The "Login" window will appear. Check
that "Operator" is shown in the “User”
field, and then press the [OK] button.
n
NOTE
When logging-in to the Utilities mode with "User:
Operator", the machine set values cannot be changed
or saved.
4
Select [ANC Auto].
Press the [024 ANC Auto] button.
Opening the nozzle station shutter
Step 2
54400-KMK-00
Opening the Utilities mode
Step 3
Select [Utilities].
Select [OK] with "User: Operator".
54401-KMK-00
Selecting [ANC Auto]
Step 4
Select [024 ANC Auto].
54402-KMK-00
4-6
4
Maintenance of options
5
Open the ANC Auto screen.
Press the [024 ANC Auto] button.
1. Select a desired table from the pull-down
menu at the upper left portion of the
screen.
2. Click the ANC figure on the right.
6
Check the ANC sensor operation.
1. Check that the nozzle storage status
shown on the screen is the same as the
actual nozzle storage status referring to
the nozzle storage position/sensor status
in the figure.
2. Remove the nozzle manually and check
that no nozzle is displayed at the target
storage position.
7
Clean the ANC.
If the nozzle detection status is different from
the actual nozzle presence status, remove
the nozzle and visually check the inside. If
any dust or chip is found, remove it and
clean the inside of the nozzle using the
vacuum assembly.
c
CAUTION
If the nozzle detection status inside the ANC does not
become stable for a reason other than clear reason,
such as dust, etc., or if the nozzle cannot be detected,
contact your distributor. The disassembly and cleaning
performed by the customer are not covered by the
warranty.
8
Close the ANC shutter.
Press the [Nozzle. Stn Shutter] button to close
the ANC shutter.
Opening the ANC Auto screen
Step 5
Select the table A or table B. Click the ANC figure.
54403-KMK-00
2-303
10
7-SP
68
Checking the ANC sensor operation
Step 6
303 nozzle to be used for head 2
Storage position: No. 10
Colored frame (red/blue/yellow/green, etc.):
Nozzle is already registered.
Special nozzle to be used for head 7
Storage position: No. 68
Black frame: Nozzle is not registered.
Gray out: Nozzle is present currently.
White: Nozzle is not present currently.
Example of nozzle storage position/sensor status
54404-KMK-00
Chapter 5 Lubrication points
Contents
1. Lubrication preparations 5-1
1.1 Compatible grease 5-1
1.2 Grease gun 5-2
2. Lubrication points/schedule (Main machine) 5-3
2.1 X-axis 5-3
2.2 Y-axis 5-4
2.2.1 YSM20R TypePV / YSM20WR 5-4
2.2.2 YSM20R TypeSV 5-5
2.3 W-axis (U-axis) 5-6
2.3.1 YSM20R Dual-stage type 5-6
2.3.2 YSM20R/YSM20WR Single-lane type 5-7
2.3.3 YSM20WR Dual-lane type 5-8
2.4 PU-axis 5-9
2.4.1 YSM20R Dual-stage type 5-9
2.4.2 YSM20R/YSM20WR Single-lane type 5-10
2.4.3 YSM20WR Dual-lane type 5-11
2.5 Head unit 5-12
2.5.1 HM head unit 5-12
2.5.2 FM head unit 5-13