YSM20R_YSM20WR_Mainte_E - 第71页

3-10 3 Periodic maintenance items 1.3 Cleaning and lubricating gripper nozzle (option) T he gripper nozzle that mounts a connector , etc. requires the periodic inspection and lubricating. n NOTE The gripper nozzle is use…

100%1 / 207
3-9
3
Periodic maintenance items
n
How to use ANC nozzle attaching/detaching tool (storing)
Attach nozzles at the nozzle station in the reverse order of detaching.
1
Check the nozzle setting position.
Check that other nozzles are not set to the nozzle storage position and the setting position is correct.
n
NOTE
Regarding the nozzle setting position, check the nozzle placement position label attached in the machine or the
machine setting.
2
Set the nozzles to the tool.
c
CAUTION
The positioning pins are in each nozzle storage position at the nozzle station to avoid setting the incorrect types of
nozzle and the incorrect nozzle setting direction. Take precautions about the nozzle setting position and the nozzle
setting direction when setting the nozzles to the tool.
3
Open the nozzle station shutter.
1. Press the emergency stop button and then open the machine safety cover.
2. Open the [Unit] - [Head] screen and press the [Nozzle. Stn Shutter] button to open the nozzle station
shutter.
4
Set the tool on the nozzle station.
1. Set the tool that the nozzles were set in Step 2 to the relevant position of the nozzle station.
2. Check that the nozzles are set securely to the nozzle station.
5
Close the nozzle station shutter.
Press the [Nozzle. Stn Shutter] button again and close the nozzle station shutter.
6
Raise the tool up.
Raise the tool up vertically and slowly and detach the nozzles from the tool.
n
NOTE
Raise the tool up vertically and slowly to avoid the nozzle tip from hitting the shutter, etc.
c
CAUTION
If raising the tool up fast and forcibly, nozzles or the nozzle station may be damaged.
3-10
3
Periodic maintenance items
1.3 Cleaning and lubricating gripper nozzle (option)
The gripper nozzle that mounts a connector, etc. requires the periodic inspection and lubricating.
n
NOTE
The gripper nozzle is used to pick up a special shape component. Select and special order a gripper nozzle fitting the
component shape.
1.3.1 Inspecting gripper nozzle
n
Checking the gripper nozzle condition
Move the grip of the nozzle with a finger. If it moves smoothly, there is no problem. If it moves back unsteadily
or is stuck in, the component pickup error or the recognition error may occur. Clean and lubricate the gripper
nozzle referring to the next page "1.3.2 Cleaning and lubricating gripper nozzle".
Additionally, check that no wear or dirt is found in the grip or operation part. If the grip is worn out, replace
the nozzle.
Inspecting gripper nozzle
Example: Type30ALD nozzle
Grip is not worn out.
No dirt or dust is found.
Grip moves smoothly.
53313-KMK-00
1.3.2 Cleaning and lubricating gripper nozzle
e
1
Remove nozzles.
1. Press the emergency stop button and
then open the machine safety cover.
2. Remove nozzles from the head. If the
machine is equipped with the nozzle
station, press the [Nozzle. Stn Shutter]
button to open the nozzle station shutter
and remove nozzles.
2
Clean the nozzle operation part.
If dust is in the gripper nozzle operation part,
remove it with an air blow tool (option), etc.
Air blow
Step2
Air blow tool
53314-KMK-00
3-11
3
Periodic maintenance items
3
Clean nozzles with an ultrasonic
cleaner.
1. Put nozzles into a container (such as
beaker) in an ultrasonic cleaner.
2. Pour ethanol in a container until nozzles
are dipped.
3. Pour water in an ultrasonic cleaner.
4. Clean nozzles with an ultrasonic cleaner
for about 10 minutes.
c
CAUTION
DO NOT pour ethanol directly into the ultrasonic
cleaner. It must be poured in a beaker or similar
container.
4
Blow nozzles.
1. Take nozzles out from an ultrasonic
cleaner.
2. Air blow entire nozzle to remove ethanol.
Intensively air blow the nozzle operation
part and the air path
5
Lubricate the nozzle.
1. Apply turbine oil to a cotton swab or tip
of a precision screwdriver slightly.
2. Apply turbine oil to the nozzle operation
part.
3. Move the nozzle several times to spread
turbine oil to the nozzle operation part.
n
NOTE
A thin coat of oil is enough to lubricate the operation
part.
6
Remove excess oil.
1. Remove excess oil by blowing the
operation part with an air blow tool.
2. Use a cotton swab or lint-free cloth to
wipe away excess oil around the
operation part.
7
Check the nozzle operation.
1. Return removed nozzles to the head. If
nozzles were removed from the nozzle
station, once return them to the nozzle
station. Press the [Nozzle Change] button
to attach nozzles to the head.
2. Press the [Vacuum] button relevant to
the head on the [Unit] - [Head] screen.
Check that the gripper nozzle closes
smoothly.
3. Press the [Vacuum] button again to
cancel vacuuming. Check that the
gripper nozzle opens smoothly.
n
NOTE
If removed nozzles from the nozzle station (option),
return them to the original storage positions.
Ultrasonic cleaner
Step3
Ultrasonic cleaner
Beaker
Pour water.
Pour ethanol
53315-KMK-00
Step4
Air blow
Air blow tool
53316-KMK-00
Lubricating gripper nozzle
Step 5
Apply turbine oil slightly with cotton swab
or precision screwdriver.
Spread turbine oil.
53317-KMK-00