User manual SIPLACE CA-Series 8 Station Extensions From software version SC.708.0 Edition 12/20 14 EN -DRAFT 8.2 Sensor for the Component Reject Bin 473 8.2 Sensor for the Component Reject Bin [001 16848-xx] Quer y compo…

100%1 / 518
8 Station Extensions User manual SIPLACE CA-Series
8.1 Nozzle Changers From software version SC.708.0 Edition 12/2014 EN -DRAFT
472
8.1.5 Component Reject Bin for the SIPLACE TwinHead
A component reject bin can be installed for the SIPLACE TwinHead. It is positioned next to the
finepitch Vision module.
8
Fig. 8.1 - 21 Component Reject Bin for the SIPLACE TwinHead
User manual SIPLACE CA-Series 8 Station Extensions
From software version SC.708.0 Edition 12/2014 EN -DRAFT 8.2 Sensor for the Component Reject Bin
473
8.2 Sensor for the Component Reject Bin
[00116848-xx] Query component reject bin X-Series/D3
The sensor for the component reject bin monitors whether the reject bin is seated correctly on its
mount.
If the reject bin was not inserted correctly, the machine cannot be started.
If the reject bin jumps out of its mount during the placement process, the machine is stopped
immediately to avoid a head crash.
Each reject bin can be monitored by a separate sensor.
8
PLEASE NOTE
When using a SIPLACE SpeedStar (C&P20 M) at a location without SWS, we recommend
that you install the optional sensor for the component reject bin.
8 Station Extensions User manual SIPLACE CA-Series
8.3 Component Camera for the TwinStar, FC Camera From software version SC.708.0 Edition 12/2014 EN -DRAFT
474
8.3 Component Camera for the TwinStar, FC Camera
8.3.1 Stationary P&P Component Camera (Type 25) 16 x 16, Digital (FC Camera)
Item no. 00119718-xx Stationary component camera 16x16 digital, type 25
8
Fig. 8.3 - 1 Stationary P&P component camera (type 25) 16 x 16, digital (FC camera)
(1) Camera housing with integral camera and camera amplifier
(2) Glass plate - illumination and lens levels below