00197498-03_UM_SiplaceCA-Serie_EN - 第100页
2 Operational Safety User Manual SIPLACE CA- Series 2.9 Residual Voltages and Discharge Times From software version SC.708.0 Edition 12/2014 EN -DR AFT 100 Fig. 2.9 - 2 Measuring points on the power supply unit 2

User Manual SIPLACE CA-Series 2 Operational Safety
From software version SC.708.0 Edition 12/2014 EN -DRAFT 2.9 Residual Voltages and Discharge Times
99
2.9 Residual Voltages and Discharge Times
2.9.1 (Placement) Machine
If the EMERGENCY STOP button is pressed or the placement system is switched off, the 250
VDC link voltage for the gantry axes and the 145 VDC link voltage for the star axes are reduced
to harmless residual voltages in a very short time.
2
2
Fig. 2.9 - 1 Power supply unit
(1) Padlock with bolt in the cover
(2) Main switch
(3) Power supply unit behind the cover
(4) Axis unit
DANGER
Dangerous voltage levels!
The machine is supplied with 3 x 208 V~, 3 x 230 V~, 3 x 380 V~, 3 x 400 V~ or
3 x 415 V~ ± 5 %, 50/60 Hz mains voltage. Parts of the system therefore carry lethally
hazardous voltages - even when the main switch is switched off.
Incorrect handling of this machine can therefore result in death or severe injury or consid-
erable damage to equipment.
Always follow the applicable accident prevention and DIN regulations (particularly EN
60204, part 1 or IEC 60204, part 1) and the applicable regulations in your own coun-
try.
The covers over the power supply unit may ONLY be opened by appropriately quali-
fied and trained personnel.

2 Operational Safety User Manual SIPLACE CA-Series
2.9 Residual Voltages and Discharge Times From software version SC.708.0 Edition 12/2014 EN -DRAFT
100
Fig. 2.9 - 2 Measuring points on the power supply unit
2

User Manual SIPLACE CA-Series 2 Operational Safety
From software version SC.708.0 Edition 12/2014 EN -DRAFT 2.9 Residual Voltages and Discharge Times
101
2.9.1.1 Residual Voltages and Discharge Times after Pressing the EMERGENCY STOP But-
ton
2
2
2.9.1.2 Residual Voltages and Discharge Times After Switching off the Main Switch
2
2
Pins X11 and X13_1
measured against X12 (GND)
Voltage in
normal mode
Residual voltage
after EMERGENCY
STOP
Discharge
times
X11 + 250 VDC < 10 VDC 7 s
X13_1 + 145 VDC < 10 VDC 50 s
Pin X13_4
measured against pin X3_7 (-
)
Voltage in
normal mode
Residual voltage
after EMERGENCY
STOP
Discharge
times
X13_4 + 40 VDC + 40 VDC -
Pins X11, X13_1 and X13_4
measured against X12 (GND)
Residual voltage when main
switch is switched off Discharge times
X11 < 10 VDC < 7 s
X13_1 < 10 VDC < 50 s
X13_4 < 10 VDC < 2 s
CAUTION
Data loss!
To avoid losing data, assess the following criteria before switching off your machine (apart
from in emergencies):
– Has the machine finished transmitting machine, setup and panel data?
– Has the machine finished processing the PCB?
– Has the machine completed the run-up phase?