5 Setting up and Commissioning User Manual SIPLACE CA-Series 5.5 Setting Up the Placement Machine From software version SC.708.0 Edition 12/2014 EN -DR AFT 290 5.5.6 Fitting the Output Conveyor 5.5.6.1 T ools – Allen key…

User Manual SIPLACE CA-Series 5 Setting up and Commissioning
From software version SC.708.0 Edition 12/2014 EN -DRAFT 5.5 Setting Up the Placement Machine
289
5.5.5 Fitting the Extension Kits to the Machine Frame
5.5.5.1 Fitting the Extension Kit to the PCB Output Side
When the placement machine is delivered, the extension kit for the PCB output side and the PCB
output conveyor are dismantled. The procedure for attaching the extension kit to the PCB output
side is as follows:
– Fitting the Output Conveyor
see section 5.5.6, page 290
– Fitting the Extension Kit to the PCB Output Side see section 5.5.7, page 291
– Installing the Axis Unit in the CA4 see section 5.5.8, page 298
– Fitting the Main Fault Indicators see section 5.5.14, page 321
– Integrating the Placement Machine into the Line see section 5.5.16, page 323
– Final Adjustment of Placement Machine see section 5.5.17, page 326
5.5.5.2 Fitting the Extension Kit to the PCB Input Side
If, for transportation reasons, the extension kit has been dismantled from the PCB input side, you
will need to perform the following steps before integrating the placement machine into the line (see
section 5.5.16
, page 323):
– Fitting the Input Conveyor
see section 5.5.9, page 301
– Fitting the Extension Kit to the PCB Input Side see section 5.5.10, page 303
– Installing the Box PC Unit on the CA4 i see section 5.5.11, page 308
– Installing the Computer Unit for the CA4 see section 5.5.12, page 314
– Installing the Axis Unit on the CA4 see section 5.5.13, page 319
– Fitting the Main Fault Indicators see section 5.5.14, page 321
– Integrating the Placement Machine into the Line see section 5.5.16, page 323
– Final Adjustment of Placement Machine see section 5.5.17, page 326

5 Setting up and Commissioning User Manual SIPLACE CA-Series
5.5 Setting Up the Placement Machine From software version SC.708.0 Edition 12/2014 EN -DRAFT
290
5.5.6 Fitting the Output Conveyor
5.5.6.1 Tools
– Allen keys, DIN 911, set
– Phillips screwdriver, size 1
5.5.6.2 Assembly
5
Fig. 5.5 - 7 Output conveyor - dual conveyor
(1) Side panel, output conveyor
(2) Side panel, processing conveyor 2
(3) Cable cover 20 x 200
(4) Countersunk screw, ISO 7046, M3x6, 2x per cable cover
(5) Cable cover 20 x 310
(6) Fillister head screw DIN 912, M3x5, 1x per cable cover
(7) Fillister head screw DIN 912, M6x16, and washer, 4 per panel
(8) Hexagonal shaft guidance
(9) Hexagonal shaft (single conveyor: one, dual conveyor: two)
(10) Drive unit

User Manual SIPLACE CA-Series 5 Setting up and Commissioning
From software version SC.708.0 Edition 12/2014 EN -DRAFT 5.5 Setting Up the Placement Machine
291
Dismantle the cable covers (item 3 and 5 in fig. 5.5 - 7) from the sides (item 1 in fig. 5.5 - 7)
from the output conveyor.
Place the side (item 1 in fig. 5.5 - 7) carefully against the side of the processing conveyor (item
2 in fig. 5.5 - 7
).
5
Fasten each side with 4 fillister head screws M6x16 and the corresponding discs (item 7 in
fig. 5.5 - 7
).
Connect the power cable to the light barriers and drive motors.
Fasten the cable covers (item 3 and 5 in fig. 5.5 - 7).
Insert the hexagonal shaft (item 9 in fig. 5.5 - 7) into the drive unit (item 10 in fig. 5.5 - 7).
Make sure that the hexagonal shaft guidance (item 8 in fig. 5.5 - 7) always points to the con-
veyor side to which the drive unit (item 10 in fig. 5.5 - 7
) is fixed.
5.5.7 Fitting the Extension Kit to the PCB Output Side
5.5.7.1 Tools
– Allen keys, DIN 911, set
– Machine key
CAUTION
Be careful not to cut through any of the light barrier or drive motor cables.