00197498-03_UM_SiplaceCA-Serie_EN - 第375页

User Manual SIPLACE CA-Series 6 Working with the Machine From software version SC.708.0 Edition 12/20 14 EN -DRAFT 6.7 Configuring the Feeder Modules 375  Shorten the component t ape with the exposed component pockets b…

100%1 / 518
6 Working with the Machine User Manual SIPLACE CA-Series
6.7 Configuring the Feeder Modules From software version SC.708.0 Edition 12/2014 EN -DRAFT
374
Check the "back" centering pin (item 3) of the feeder module as you do so. This must slide
easily into the recess (item 5) in the centering bar, otherwise the feeder module is not seated
vertically on the component table or it was not placed on the guide profile (item 8) correctly.
The locking latch (item 7) engages with the locking roller of the feeder (item 1 in fig. 7.1 - 2).
If you have forgotten to engage the removal handle (item 1 in fig. 6.7 - 2
, page 372) the status
display
on the feeder module's operator panel will light up red after a few seconds. The LCD display
contains the error message "Handle --->>" (see fig. 6.9 - 1
, page 379). 6
Engage the removal handle (item 1 in fig. 6.7 - 2). The feeder module's status display
now lights up green and the feeder module is on standby. The track number and con-
veyor increment can be read on the LCD display once more.
6.7.4 Inserting the Component Tape into the X feeder Module
6.7.4.1 Checking the X Tape Feeder Module
When you place the component tape in the feeder module, first check whether there are
any components in the vicinity of the pickup window (item 2 in fig. 6.7 - 5
).
Remove any components that you find since they could cause a fault.
6.7.4.2 Preparing the Component Tape for Insertion
Check that there is a straight cut edge at the start of the component tape.
If the transport holes are torn or bent, cut off this part of the tape.
Also make sure that there are no streaks of adhesive on the cover foil.
Pull around 30 cm cover foil away from the component tape if this does not expose any
components.
6
PLEASE NOTE
Avoid loss of components
If there is not enough cover foil available, use the SMD tape threader
for the 8 mm tape:Item no. 00355265-xx
for the 12 mm - tape:Item no. 00356342-xx
User Manual SIPLACE CA-Series 6 Working with the Machine
From software version SC.708.0 Edition 12/2014 EN -DRAFT 6.7 Configuring the Feeder Modules
375
Shorten the component tape with the exposed component pockets by around 3 cm.
Remove the components from the open tape pockets.
Wrap the cover foil around the front edge of the tape along the bottom of the tape.
6.7.4.3 Inserting the Tape into the X Feeder Module
6
Fig. 6.7 - 4 Inserting the component tape
(1) Entry to the tape guide channel
(2) Operator panel
(3) Tape guide channel outlet
(4) Pickup window
(5) Lever for raising the pickup window
6
Hold the component tape so that the transport holes are on the left-hand side viewed in the
direction of travel.
Push the component tape into the entry (item 1 in fig. 6.7 - 4) to the tape guide channel and
further until it emerges from the exit opening (item 3 in fig. 6.7 - 4
).
Pull the component tape up and out, and fold the cover foil back against the top of the tape.
6 Working with the Machine User Manual SIPLACE CA-Series
6.7 Configuring the Feeder Modules From software version SC.708.0 Edition 12/2014 EN -DRAFT
376
Guide the start of the tape beneath the pickup window (item 2 in fig. 6.7 - 5) and further until
the component tape is touching the sprocket wheel.
6
Fig. 6.7 - 5 Pickup window on the tape feeder module
(1) Tape support, removable
(2) Pickup window
(3) Removal edge for the cover foil
(4) Component pickup area
(5) Lever for raising and latching the pick-up window