00197498-03_UM_SiplaceCA-Serie_EN - 第379页

User Manual SIPLACE CA-Series 6 Working with the Machine From software version SC.708.0 Edition 12/20 14 EN -DRAFT 6.8 Setting Up the X Feeder Module 379 6.8 Setting Up the X Feeder Module The configuration of the X feed…

100%1 / 518
6 Working with the Machine User Manual SIPLACE CA-Series
6.7 Configuring the Feeder Modules From software version SC.708.0 Edition 12/2014 EN -DRAFT
378
6
Fig. 6.7 - 7 Guiding the cover foil to the foil packing wheels
(1) Cover foil packing wheels
(2) Cover foil
6
On the operator panel, press the FOIL button (item 3 in fig. 6.7 - 6) until the cover foil is ten-
sioned. The cover foil rocker points down and stops the drive motor.
Cut the component tape flush with the front end of the feeder module.
User Manual SIPLACE CA-Series 6 Working with the Machine
From software version SC.708.0 Edition 12/2014 EN -DRAFT 6.8 Setting Up the X Feeder Module
379
6.8 Setting Up the X Feeder Module
The configuration of the X feeder modules is described in the relevant job guide.
6.9 LCD and Status Displays on the X Feeder Module
The X feeder modules have a multicolor status display (item 6) for signaling the operating statuses
and an LCD display (item 1) to display the texts.
If the status display lights up green, the feeder module is on standby and is contained in
the current setup. If the feeder module is not contained in the current setup, the status
display remains off.
If the status display lights up orange, it is signaling a warning. The text of the warning
appears on the LCD display.
If the status display lights up red, a malfunction has occurred. The error message is is-
sued on the LCD display.
6
Fig. 6.9 - 1 Buttons, LCD and status displays on the X feeder module
The following tables contain the wording of the LCD display, the color and the mode of the status
display, its meaning and troubleshooting measures.
(1) LCD display (2) FORWARD button
(3) BACK button (4) FOIL button
(5) SET button (6) Status display, multicolor
6 Working with the Machine User Manual SIPLACE CA-Series
6.9 LCD and Status Displays on the X Feeder Module From software version SC.708.0 Edition 12/2014 EN -DRAFT
380
6.9.1 Warnings
6
6
6.9.2 Error Messages and Troubleshooting
6
Text on the
LCD display
Status
display
Meaning Solution
Remove Foil
(Remove the foil)
Orange The selected function is not
permitted when the cover foil
is tensioned (foil rocker is
pressed down).
If you wish to carry out that function, remove
the foil from the pair of gear wheels and cut
it off to relieve the pressure on the foil rocker.
Text on the
LCD display
Status
display
Meaning Solution
None Red,
flashing
Feeder module software not
jumping to the application
Reload the application software
Load feeder module software
Handle --->>
(Handle --->>)
Red Feeder module was sig-
naled, but removal handle is
not yet pushed in
Push in the removal handle
Low Voltage
(Low voltage)
Orange 24V supply voltage did not
rise above the switch-on
threshold after switching on
Check the power supply
Low Voltage
(Low voltage)
Red 24V supply voltage rose
above the switch-on thresh-
old after switching on and
was then interrupted
Check the power supply
Feed Timeout
TransTimeout
(Timeout in tape
feeder cycle)
Red Tape feeder cycle did not
end correctly within the spec-
ified time (timeout for the
"Feed" function)
Is the tape reel jammed in the container?
Is there a component jammed in the pick-up
area between component tape and compo-
nent window?
Once the obstacle has been eliminated, use
the arrow keys to restart the conveyor. The
feeder module will move the defective con-
veyor to the end, and then returned to its
position
Foil Torn
(Foil torn)
Red Foil was not tensioned within
the specified time
The foil is probably torn. Insert new foil and
tension
Foil PeelErr
(Error while peel-
ing off the foil)
Red Foil was not peeled off even
though the tape is moved
The cover foil is probably jammed beneath
the pick-up window and cannot be peeled
off correctly