00197498-03_UM_SiplaceCA-Serie_EN - 第395页
User Manual SIPLACE CA-Series 6 Working with the Machine From software version SC.708.0 Edition 12/20 14 EN -DRAFT 6.15 Observing the Indicator Lamps for Operating States 395 unchanged off on Transpor t error, left uncha…

6 Working with the Machine User Manual SIPLACE CA-Series
6.15 Observing the Indicator Lamps for Operating States From software version SC.708.0 Edition 12/2014 EN -DRAFT
394
unchanged flashes (7,7) unchanged Waiting for setup data
unchanged flashes (7,7) unchanged Waiting for cluster data
unchanged flashes (7,7) unchanged Load table program
unchanged flashes (7,7) unchanged Position detection
unchanged flashes
(1,10)
unchanged Bad fiducial detection
unchanged flashes (7,7) unchanged Nozzle configuration test
unchanged flashes (7,7) unchanged Feeder position detection
unchanged flashes (7,7) unchanged One track is empty
unchanged flashes (7,7) unchanged No further track available
unchanged flashes (7,7) unchanged Go to refill position
unchanged flashes (7,7) unchanged Transport being initialized
unchanged flashes (7,7) unchanged Place PCB in input conveyor
flashes (1,10) flashes (7,7) unchanged Remove PCB from output conveyor
unchanged flashes (7,7) flashes (1,10) Remove PCB from output conveyor 2
flashes (1,10) flashes (7,7) flashes (1,10) Width adjustment
unchanged flashes
(1,10)
unchanged Transport PCB
flashes (1,10) flashes (7,7) flashes (1,10) Both output conveyors are cleared
on flashes
(1,10)
on Transport error
on off on Go to service position
on Placement
flashes
(1,20)
Waiting for processing data
Error display
on off unchanged Machine error, right
on off unchanged Track empty, right
on off unchanged Nozzle configuration, right
on off unchanged Transport error, right
on off on Fiducial error, left and right
on off on Fiducial error, left and right
unchanged off on Track empty, left
unchanged off on Nozzle configuration, left
L1 (white)
(right lamp)
L2 (green) L3 (white)
(left lamp)
Meaning

User Manual SIPLACE CA-Series 6 Working with the Machine
From software version SC.708.0 Edition 12/2014 EN -DRAFT 6.15 Observing the Indicator Lamps for Operating States
395
unchanged off on Transport error, left
unchanged off on Machine error, left
Pickup error display
unchanged unchanged flashes (1,20) First track empty, left
unchanged unchanged flashes (5,20) Other tracks empty, left
unchanged unchanged flashes (5,5) Second to last track is being used
unchanged unchanged flashes (1,2) Last track is being used, left
flashes (1,20) unchanged unchanged First track empty, right
flashes (5,20) unchanged unchanged Other tracks empty, right
flashes (5,5) unchanged unchanged Second to last track is being used, right
flashes (1,2) unchanged unchanged Last track is being used, right
L1 (white)
(right lamp)
L2 (green) L3 (white)
(left lamp)
Meaning

6 Working with the Machine User Manual SIPLACE CA-Series
6.15 Observing the Indicator Lamps for Operating States From software version SC.708.0 Edition 12/2014 EN -DRAFT
396