00197498-03_UM_SiplaceCA-Serie_EN - 第449页

User manual SIPLACE CA-Series 8 Station Extensions From software version SC.708.0 Edition 12/20 14 EN -DRAFT 8.1 Nozzle Changers 449 8.1.2 Nozzle Changers for th e SIPLACE SpeedSt ar (C&P20 M) 8 Fig. 8.1 - 3 Nozzle c…

100%1 / 518
8 Station Extensions User manual SIPLACE CA-Series
8.1 Nozzle Changers From software version SC.708.0 Edition 12/2014 EN -DRAFT
448
8
Fig. 8.1 - 1 Nozzle changer on SWS - example for use at location 1 and 3
8
Fig. 8.1 - 2 Nozzle changer on the SWS - reject bin
User manual SIPLACE CA-Series 8 Station Extensions
From software version SC.708.0 Edition 12/2014 EN -DRAFT 8.1 Nozzle Changers
449
8.1.2 Nozzle Changers for the SIPLACE SpeedStar (C&P20 M)
8
Fig. 8.1 - 3 Nozzle changers for the SIPLACE SpeedStar (C&P20 M)
This nozzle changer can hold up to 6 magazines, each with 12 nozzle holders. The magazines
are seated on a common support. They are centered with two parallel pins and fixed in place with
4 snap fasteners.
The correct seat of the magazines on the basic nozzle changer body is monitored by micros-
witches, to prevent a collision of the placement head with any magazines projecting upwards. All
magazine locations must be filled since the safety circuit stops the machine in response to missing
magazines or magazines that are not seated correctly.
8.1.2.1 Position of the Nozzle Changers for the C&P20 Head on the CA4 Machine
The locations 1, 2, 3 and 4 can accommodate up to 2 nozzle changers for the SIPLACE SpeedStar
(C&P20 M) (item 1 and 2 in fig. 8.1 - 4
). This gives a total capacity of 8 nozzle changers with 48
magazines and a total of 576 nozzle holders.
8 Station Extensions User manual SIPLACE CA-Series
8.1 Nozzle Changers From software version SC.708.0 Edition 12/2014 EN -DRAFT
450
8
Fig. 8.1 - 4 Position of nozzle changers for the SIPLACE SpeedStar (C&P20) - example
8
8
(1) Nozzle changer, "row 1"
(2) Nozzle changer, "row 2"
(3) Reject bin for components
(4) Take-off device and reject bin for nozzles
(5) Nozzle magazine
PLEASE NOTE
When an SWS with a C&P20 nozzle changer is used, one row is installed by default. A
second row is available on request.