00197498-03_UM_SiplaceCA-Serie_EN - 第457页
User manual SIPLACE CA-Series 8 Station Extensions From software version SC.708.0 Edition 12/20 14 EN -DRAFT 8.1 Nozzle Changers 457 Place the magazine on the snap fastener b alls (item 5 in fig. 8.1 - 7 ). Press the…

8 Station Extensions User manual SIPLACE CA-Series
8.1 Nozzle Changers From software version SC.708.0 Edition 12/2014 EN -DRAFT
456
8
Fig. 8.1 - 7 Changing the magazine
(1) Lever for raising the magazine
(2) Parallel pin, engages in the hole in the magazine
(3) Spring pin for triggering the microswitch
(4) Pin of the slide mechanism, moves the locking plate
(5) Ball of snap fastener
(6) Parallel pin, engages in the slot in the magazine
(7) Locking plate in the "magazine locked" position
8
PLEASE NOTE
Move the locking plate into the "Magazine locked" position.
Before inserting, align the magazine so that the centering pins (item 2 and 6 in fig. 8.1
- 7) can slide into the centering hole and the slot (item 6 in fig. 8.1 - 6) .

User manual SIPLACE CA-Series 8 Station Extensions
From software version SC.708.0 Edition 12/2014 EN -DRAFT 8.1 Nozzle Changers
457
Place the magazine on the snap fastener balls (item 5 in fig. 8.1 - 7).
Press the magazine down evenly so that the snap fastener balls engage in all the snap fas-
teners at the same time.
8.1.2.7 Position detection
Each magazine of the nozzle changer has two fiducials: one for determining the position and one
for determining the angular position.
8
Fig. 8.1 - 8 Nozzle magazine - garage numbering, fiducials for determining the position and angular position
(1) Locking plate in the "magazine open" position
(2) Fiducial for determining the position
(3) Fiducial for determining the angular position

8 Station Extensions User manual SIPLACE CA-Series
8.1 Nozzle Changers From software version SC.708.0 Edition 12/2014 EN -DRAFT
458
8.1.2.8 "Row 2" Nozzle Changers for the SIPLACE SpeedStar (C&P20 M)
[00119716-xx] Nozzle changer 2, X-Series, C&P20
The "row 2 " nozzle changer can be fitted at the following locations, if no SWS is installed there:
CA4 machine: Locations 1, 2, 3 and 4 (see fig. 8.1 - 4
, page 450)
The retrofit package contains the nozzle changer and an assembly kit.
8
Fig. 8.1 - 9 Assembly kit for the "row 2" nozzle changer